Handle Assembly

1. Carefully unpack all components,

set aside packaging.

2. Lift vacuum body to upright position.

3. Remove the screw (1) that comes

attached to the

body.

4. From the rear of

the vacuum, align

the handle with

groove and slide

onto vacuum. If

necessary, use

thumb and finger

pressure to slide

handle into position.

5. Once handle is in place, secure the

handle with the screws (2). (Fig. 1)

Caution:

Do not over tighten. Over

tightening could strip the screw holes.

Do not operate the vacuum without

the handle screws in place.

Fig. 1

Cord Assembly

1. Make sure that the quick release

cord holder is in the upright

position.

2. Remove the wire

tie from the power

cord.

3. Wrap the cord into

place by wrapping

it in a clockwise

direction around

the quick release

cord holder and

the lower cord

holders. (Fig. 2)

4. Turn the quick

release cord holder

to the left or to the right to unwrap

the power cord. (Fig. 2)

Warning:

Always make sure that the

vacuum is turned off

before unplugging.

Fig. 2

OPERATING INSTRUCTIONS

Assembling Your Vacuum Cleaner
Note:

Do not plug the power cord

into an electrical outlet until

the vacuum is fully

assembled.

4

Using the Attachments

1.

Place vacuum in its upright position.

Make sure that the vacuum cleaner

is NOT plugged into the electrical

outlet when adding or removing

accessories.

2.

Turn the carpet height selector

to the highest position and set the

Carpet to Floor selector to the

“Floor” position.

3.

Remove the hose connector from

the rear of the unit and push in the

desired attachment firmly onto the

end of the hose.

4.

If additional length is required,

attach the extension tubes to the end

of the hose and then attach the

crevice tool, round brush or

upholstery brush to the end of the

extension tube.

Warning:

Avoid tipping the vacuum or

setting it on furniture, fringed area rugs or

carpeted stairs while you are using the

hose with the attachments. When using

the unit to vacuum floors or with

attachments, set the Carpet to Floor

Selector to the “Floor” position. This will

stop the beater brush from rotating. When

vacuuming carpets, avoid leaving the

vacuum in one place for an extended

period of time, particularly on thick carpet.

How to Start

The upright vacuum can be used on

multiple types of carpeting, bare floors or

upholstery with attachments. When using

the attachment tools such as the crevice

tool, round brush or the upholstery brush,

place the handle of the vacuum in the

upright position.

1. Turn the quick release cord holder

to either side 180° to release the

power cord.

2. Plug the power cord into the electrical

outlet.

3. Push the On/Off

button to the "On"

position to turn

the vacuum on.

4. To release the

handle, step

on the power

head and pull the handle back.

5. When using the attachments, the

vacuum must be in the upright

position. (Fig. 3)

Caution:

Do NOT pull the vacuum

cleaner around the room by the hose as it

could tip over and cause damage. When

using the attachments, do NOT over

extend the hose length when reaching.

Trying to reach beyond the hose reach

could cause the vacuum to tip over.

Fig. 3

Changing the Headlight Bulb

OPERATING INSTRUCTIONS

6. Remove the belt cover (Fig. 22, #1)

7. Lift the right side of the brush bar

first and then lift the left hand side.

(Fig. 22 #2, #3)

8. Remove the brush bar from the

power head. (Fig. 22, #4)

9. Carefully remove any belt residue

that may exist in the belt area before

replacing with a new belt.

10. Remove the worn or broken belt

from the motor drive shaft.

11 Loop the new belt first over the motor

drive shaft and then over the agitator

pulley.

1. Turn unit “Off” and unplug from wall

outlet.

2. With a flat head screw driver, snap off

the lens cover by pressing down on the

two notches on the lens cover. (Fig. 23)

3. Lift off the head light lens.

Warning:

To reduce the risk of electric

shock, the power cord must be

disconnected before removing the dust

cup, HEPA filter,changing the filters or

performing maintenance/trouble shooting

checks.

Fig. 22

Notches

Fig. 23

4. Remove the light bulb by pulling it

out carefully.

5. Replace the new bulb by pushing

it in.

6. Replace the head light lens by pushing

it in so that it snaps back in place.

12. Insert the right side of the brush

bar in first by placing the end cap

down into the slot and then do the

same with the left side. Press

firmly to make sure that each end

is completely inserted.

13. Check to make sure that the belt is

centered on the agitator pulley and

that the brush bar turns.

14. Replace the belt cover.

15. Replace the power head cover and

turn the unit over carefully.

16. Replace the lower plate, screwing

in the four (4) outer screws first.

17. When screwing in the center screw,

hold the carpet height adjustment

knob from the outside and screw in

the last screw.

18. Replace the lower plate.

19. Once the lower plate is attached,

replace the base plate with the four

(4) screws.