PROBLEM SOLVING
GETTING TO KNOW YOUR CYCLONIC BAGLESS
UPRIGHT
This appliance was inspected thoroughly and was in good operating condition when it
was shipped from the factory. If a minor problem occurs, it usually can be solved quite
easily when the cause is found. Therefore, this checklist is provided for your
convenience.
PROBLEM POSSIBLE
CAUSE
POSSIBLE
Cleaner Won’t
Run
1. Not properly plugged into
wall outlet.
2. No electricity in wall outlet.
3. On/Off switch not turned on.
4. Motor thermostat tripped.
5. Blown fuse/tripped breaker.
1. Plug in firmly.
2. Check fuse or breaker.
3. Push on/off switch to on
4. Reset motor thermostat. (page 8 )
5. Reset circuit breaker or replace
fuse.
Cleaner Won't
Pick Up
1. Full or clogged dust cup.
2. Wrong pile height setting.
3. Clogged
nozzle.
4. Clogged
dust
inlet
port.
5. Clogged
hose.
6. Broken
belt.
7. Hose not inserted fully.
8. Dirty
filters.
9. HEPA filter needs cleaning
or replacing.
10. HEPA filter frame needs
cleaning.
1. Clean
dust
cup.
(page
5)
2. Adjust setting. (page 5)
3. Remove
obstruction.
4. Remove power head cover and
remove obstruction.
5. Remove
obstruction.
6. Replace belt. (page 8)
7. Push
hose
in
securely.
8. Clean / change filters. (page 7)
9. Clean or replace HEPA filter.
(page 6)
10. Clean HEPA filter frame. (page 6)
Cleaner Picks
Up Moveable
Rugs Or
Pushes Too
Hard
1. Wrong pile height setting.
1. Adjust setting. (page 5)
Agitator Does
Not Turn
1. Broken
belt.
2. Belt installed incorrectly.
1. Replace belt. (page 8)
2. Check belt changing and agitator
cleaning. (page 8)
Air Flow
Restricted
With
Attachment
Use Sound
Changes
1. Attachment use restricts air
flow.
2. New carpet debris clogging
air path.
1. Check
attachment.
(page
4)
2. Remove
obstruction.
10. Flexible Hose
11. Power Cord
12. Quick Release Power Cord Holder
13. Round Brush
14. Upholstery Brush
15. Crevice Tool
16. Extension Tubes (x2)
17. Hose Connector
18. Carpet-to-Floor Selector
1. Upper Handle
2. On/Off Switch
3. Dust Cup Release Button
4. Dust Cup
5. HEPA Filter Frame
6. Carpet Height Selector
7. Furniture Guard
8. Head Light
9. Motorized Power Head
Technical Specifications
Voltage:
120V., 60Hz.
Power:
12 Amps
Note: Illustrations may differ from actual unit.