WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Swing securing bracket over end of lamp and hand-tighten the provided
17.
wing nut on stud. (See Figure 13)
Plug ballast plug into end of lamp and reconnect power supply.
18.
(See Figure 14)
Flip the red power switch to the on position. (Light on switch should be on
19.
indicating power.)
Look through view port to be sure lamp is working. You should see a
20.
blue glow. (The view port is covered with a plastic lens that blocks the
UVC rays.)
If the lamp is not glowing, make sure the wiring is correct and
21.
that the ballast is plugged in securely to lamp. If lamp still does
not glow, contact technical support at 1-252-522-3031 for
further assistance.
After unit has been found to be working properly, note date of
22.
installation on inside cover, close cover and engage latch. Apply
supplied wire tie to latch or other locking mechanism to
provide safety.
Figure 13
Figure 14
BULB MOUNTING BRACKET SELECTION AND INSTALLATION
The UV-AIRE units come with an angled mounting bracket and flat mounting bracket to position the bulb either
straight or at an angle. Choose the bracket method best suited for your needs. Refer to the configurations
chart below when making your selection.
Good
Better
Standard 90° Installation
(Flat Bracket)
(Fits a minimum 12” Duct)
Standard 90° Installation
(Flat Bracket)
(Fits a minimum 18” Duct)
Patent Pending 45° Installation
(Angled Bracket)
(Fits a minimum 8” Duct)
Patent Pending 45° Installation
(Angled Bracket)
(Fits a minimum 14” Duct)
UV-Aire Configurations