4.2 Boil-Out Procedure

DANGER

Never leave the fryer unattended during the boil-out process. If the boil-out solution

boils over, turn the fryer off immediately and let the solution cool for a few minutes

before resuming the process. To lessen the chance of boil over, turn the fryer’s gas

valve knob to the PILOT position occasionally.

WARNING

Do not drain boil-out solution into a shortening disposal unit, a built-in filtration unit,

or a portable filter unit. These units are not intended for this purpose, and will be

damaged by the solution.

DANGER

Remove all drops of water from the frypot before filling with cooking oil or

shortening. Failure to do so will cause spattering of hot liquid when the oil or

shortening is heated to cooking temperature and may cause injury to nearby

personnel.

A. Pour cleaning solution into the frypot and add water to the bottom OIL LEVEL line scribed

in the back of the frypot.

B. Operating thermostat-equipped fryers: Set dial/temperature controller to 225°F (107ºC), just

above that of boiling water.

C. Filtration/Boil-Mode equipped fryers: Turn fryer power switch to "ON". Press the fryer-

reset switch (if applicable). Turn the boil-out switch "ON".

CAUTION

If the pilot and main burner go out, the fryer(s) MUST be left completely shut down at

least 5 minutes before lighting.


D. The main burner will ignite.

E. When the solution nears boiling point, reset the temperature controller to 200°(93ºC).

F. The burners should shut off just as the water starts to boil.

CAUTION

Do not leave fryer unattended. The boil-out solution may foam and overflow if fryer is

left unattended. Press ON/OFF switch to the "OFF" position (Filtration/Boil-Mode

equipped fryers) or reduce temperature (Operating Thermostat equipped fryers) to

control this condition.