Summary of audible/visual notifications, Alpha display keypads) – First Alert FA142C User Manual
Page 34
– 3 4 –
SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
(ALPHA DISPLAY KEYPADS)
S O U N D
C A U S E
D I S P L A Y
LOUD, INTERRUPTED*
Keypad & External
FIRE ALARM
FIRE
is displayed; descriptor of zone in alarm is displayed.
LOUD, CONTINUOUS*
Keypad & External
BURGLARY/AUDIBLE
EMERGENCY ALARM
ALARM
is displayed; descriptor of zone in alarm is also displayed..
Also see "Exit Alarm Warning Displays and Sounds" on page 21.
ONE SHORT BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE
c. BYPASS VERIFY
a.
DISARMED/READY TO ARM
is displayed. Green READY indicator is lit.
b. The number and descriptor of the open protection zone is displayed.
Green READY indicator (if present) is not lit.
c. Numbers and descriptors of the bypassed protection zones are displayed (One beep is
heard for each zone displayed). Subsequently, the following is displayed:
DISARMED
BYPASS Ready to Arm
ONE SHORT BEEP every
40 sec. Keypad only
SYSTEM IS IN TEST MODE
Opened Zone identifications will appear.
ONE BEEP every 40 sec.
Keypad only
a. LOW BATTERY AT A XMTR
b. SYSTEM MAIN BATT. WEAK
c. TROUBLE
a.
LO BAT
displayed with description of transmitter.
b.
LO BAT
displayed with no transmitter description.
c.
CHECK
displayed. Descriptor of troubled protection zone is displayed.
TWO SHORT BEEPS
Keypad only
ARM AWAY OR MAXIMUM
ARMED AWAY
or
ARMED MAXIMUM
is displayed. Red ARMED indicator is lit.
THREE SHORT BEEPS
Keypad only
a. ARM STAY OR INSTANT
b. ZONE OPENED WHILE SYS-
TEM IS IN CHIME MODE
c. ZONE OPENED WHILE SYS-
TEM IS IN TEST MODE
a.
ARMED STAY
or
ARMED INSTANT
is displayed. Red
ARMED indicator is lit.
b.
CHIME
displayed. Pressing
✴
/ READY key will display descriptor of opened zone.
c. Open protection zone descriptor is displayed.
RAPID BEEPING
Keypad only
MEMORY OF ALARM
FIRE
or
ALARM
is displayed; descriptor of zone in alarm is displayed.
SLOW BEEPING
Keypad only
a. ENTRY DELAY WARNING
b. EXIT DELAY ALERT
(if programmed)
a.
DISARM SYSTEM OR ALARM WILL OCCUR
is displayed. Exceeding the delay time
without disarming causes alarm.
b.
ARMED AWAY
or
ARMED MAXIMUM
is displayed. Slow beeps change to fast during
last 5 sec of exit delay.
*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is steady ring.
Note:
Also see
Other Trouble Displays
and
Total Power Failure
under
TROUBLE CONDITIONS
on pages 27 and 28.