SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS

(ALPHA DISPLAY KEYPADS)

S O U N D

C A U S E

D I S P L A Y

LOUD, INTERRUPTED*
Keypad & External

FIRE ALARM

FIRE

is displayed; descriptor of zone in alarm is displayed.

LOUD, CONTINUOUS*
Keypad & External

BURGLARY/AUDIBLE
EMERGENCY ALARM

ALARM

is displayed; descriptor of zone in alarm is also displayed..

Also see "Exit Alarm Warning Displays and Sounds" on page 21.

ONE SHORT BEEP
(not repeated)
Keypad only

a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT

WITH AN OPEN ZONE

c. BYPASS VERIFY

a.

DISARMED/READY TO ARM

is displayed. Green READY indicator is lit.

b. The number and descriptor of the open protection zone is displayed.

Green READY indicator (if present) is not lit.

c. Numbers and descriptors of the bypassed protection zones are displayed (One beep is

heard for each zone displayed). Subsequently, the following is displayed:

DISARMED

BYPASS Ready to Arm

ONE SHORT BEEP every
40 sec. Keypad only

SYSTEM IS IN TEST MODE

Opened Zone identifications will appear.

ONE BEEP every 40 sec.
Keypad only

a. LOW BATTERY AT A XMTR
b. SYSTEM MAIN BATT. WEAK
c. TROUBLE

a.

LO BAT

displayed with description of transmitter.

b.

LO BAT

displayed with no transmitter description.

c.

CHECK

displayed. Descriptor of troubled protection zone is displayed.

TWO SHORT BEEPS
Keypad only

ARM AWAY OR MAXIMUM

ARMED AWAY

or

ARMED MAXIMUM

is displayed. Red ARMED indicator is lit.

THREE SHORT BEEPS
Keypad only

a. ARM STAY OR INSTANT

b. ZONE OPENED WHILE SYS-

TEM IS IN CHIME MODE

c. ZONE OPENED WHILE SYS-

TEM IS IN TEST MODE

a.

ARMED STAY

or

ARMED INSTANT

is displayed. Red

ARMED indicator is lit.

b.

CHIME

displayed. Pressing

/ READY key will display descriptor of opened zone.

c. Open protection zone descriptor is displayed.

RAPID BEEPING
Keypad only

MEMORY OF ALARM

FIRE

or

ALARM

is displayed; descriptor of zone in alarm is displayed.

SLOW BEEPING
Keypad only

a. ENTRY DELAY WARNING

b. EXIT DELAY ALERT

(if programmed)

a.

DISARM SYSTEM OR ALARM WILL OCCUR

is displayed. Exceeding the delay time

without disarming causes alarm.

b.

ARMED AWAY

or

ARMED MAXIMUM

is displayed. Slow beeps change to fast during

last 5 sec of exit delay.

*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is steady ring.