beautypg.com

Fedders FV95A090 User Manual

Page 39

background image

T

C

8

S

1

O

D

M

70-4

Cool

Cool

1

b

1150

1On

1000

3

a

A

2

Off

810

1

Off

650

2.5

B

2

On

1

On

2C

2

On

1

On

1.5

D

A

B

B

C

D

A

B

C

C

D

1550

4

1350

1150

3.5

1000

810

3

a

2.5

2

S3

2
1
2
1
2
1
2
1
2
1
2

On

Off
Off

On

Off
Off

On
On
On
On
On

S3

85-4

All

Delay

5

5

Off

6

On

5

On

6

On

5

On

T

No

delay

No

delay

1

30
30

Off

0

On

C

B

D

S4

6On

S

180

30

Off

On

Model

Desc. Bank

Switch

Pos.

CFM

AC

Ton

Tap

1

Off

1350

3.5

b

A

2

Off

1150

1On

3

a

A

2

Off

810

1

Off

2

On

1

On
On

A

B

B

C

S3

Switch

ADJUSTING BLOWER SPEEDS

Cooling Mode

The unit is factory set to provide the highest airflow.
Adjustments can be made to match the furnace with a small-
er cooling coil by changing the DIP switch or jumper settings,
located on the integrated ignition control board. Refer to

Heating Mode

The unit is set from the factory to operate at the center of
the temperature rise range. For this model furnace, the air

airflow can be increased or decreased by changing the
heating mode DIP switches or jumpers, located on the inte-
grated ignition control board, to the Nominal-plus/minus
settings. Please note that Nominal-plus will decrease the
air temperature rise and the Nominal-minus will increase
the air temperature rise. At the end of a call for heat, the
main blower has a fixed off delay at a reduced airflow to
remove residual heat from the heat exchanger.

the Cooling DIP switch or jumper settings table for instructions
on how to set the switches. Please note that if the furnace is
to be matched to the lowest airflow for cooling, the "Adjust"
DIP switches or jumper setting must be set to the decreased
setting. When using this setting, it is recommended that the

Plus.

temperature rise is between 35 and 65 degrees F. Heating

Make adjustments to the controller with the electrical
power off.

WARNING

front blower shroud from furnace.

How To Remove The Blower

1. Disconnect power from furnace.
2. Remove thermostat wiring from the integrated furnace

control.

3. Remove L1, Neutral and Ground connections between

the integrated furnace control and the Furnace
electrical connection junction box.

4. Remove 12 pin male molex connector from female

connection point, and ground connection from
integrated furnace control.

5. Unscrew 2 blower housing bolts located in the front

6. Slide blower assembly towards front of furnace. Blower

is mounted on rail system, and will slide forward about
10 inches before blower is clear of rails.

6. Turn on power to the furnace.

integrated furnace control.

connection point, and ground connection to the

5. Connect 12 pin male molex connector to female

electrical connection junction box.

the integrated furnace control and the furnace

4. Connect L1, Neutral and Ground connections between

control.

3. Connect thermostat wiring to the integrated furnace

tighten.

blower housing. Insert blower housing bolts and

blower rails. Insert blower shroud on the front of the

urnace ensuring blower assembly is correctly placed in

blower rails. Push blower assembly towards back of

compartment. Line up blower assembly to slide into

2. Keep blower assembly tight to top of blower

1. Place blower into blower compartment.

How To Install The Blower

Ensure that there is a drip bend in the connect wires to
the blower motor to prevent condensate from following
the wire into the connector.

WARNING

Bolts

BLOWER BOLTS

FIGURE 15

blower shroud as indicated in figure 15 (right). Remove

37

Heating DIP switches or jumper setting be set for Nominal-