Service, Ps-pro ii specifications – Furman Sound PS-PRO II User Manual
Page 11
P S - P R O I I - P O W E R C O N D I T I O N E R / S E q u E N C E R
10
liability or otherwise. Under no circumstances,
whether based on this Limited Warranty or
otherwise, shall Manufacturer be liable for in-
cidental, special, or consequential damages.
Manufacturer’s employees or representatives’
ORAL OR OTHER WRITTEN STATEMENTS
DO NOT CONSTITUTE WARRANTIES, shall
not be relied upon by Purchaser, and are not a
part of the contract for sale or this limited war-
ranty. This Limited Warranty states the entire
obligation of Manufacturer with respect to the
Product. If any part of this Limited Warranty is
determined to be void or illegal, the remainder
shall remain in full force and effect.
PS-PRO II SPecIfIcatIOnS
SERVICE
Before returning any equipment for repair, please
be sure that it is adequately packed and cush-
ioned against damage in shipment, and that it is
insured. We suggest that you save the original
packaging and use it to ship the product for
servicing. Also, please enclose a note with your
name, address, phone number and a description
of the problem.
NOTE: All equipment being returned for repair
must have a Return Authorization (RA) Number.
To get an RA Number, please call the Furman
Service Department, (707) 763-1010, Ext. 120 or
121, between 8 am and 5 pm U.S. Pacific Time.
Please display your RA Number prominently on
the front of all packages.
Current Rating:
20 Amps (2400 Watts at 120 VAC)
(
16 Amps for "E" version)
Input Voltage:
85 to 264 VAC without damage
Delay Intervals:
Total elapsed ON or OFF delay time adjustable
from 1-60 seconds, with a single trimpot
ON Sequence:
-Delay 1 outlets go on immediately with switch.
-Delays between outlets 1 and 2, and 2 and 3,
adjustable from 1-60 seconds each
OFF Sequence:
-Delay 3 outlets go off immediately with switch.
-Delays between outlets 3 and 2, and 2 and 1,
same as ON delays
Remote Switch:
Screw terminals, 2 for switch, 2 additional for
optional LED (22 ga. minimum)
Spike Protection Modes:
Line to neutral, zero ground leakage
Spike Clamping Voltage:
188 Vpk @ 3,000 amps, (133 VAC RMS)
[“E” Version: 376 Vpk (266 VAC RMS)]
Response Time:
1 nanosecond
Maximum Surge Current:
6,500 amps
Dimensions:
1.75” H x 19” W x 10.5” D.
Weight:
12 lbs.
Construction:
Steel chassis, .125” brushed and black anodized
aluminum front panel; glass epoxy printed circuit boards
Power Consumption:
11 watts
Safety Agency Listings:
CE, NRTL-C
Over Voltage Shutdown:
US: 140V HI, 80V LO
E: 280V HI, 150V LO
Optional:
220/240V Versions (units with “E” suffix only) are
intended for use in countries with nominal 220 to