background image

A R - 1 2 1 5 A C L I N E V O LTA G E R E G U L ATO R

convenience outlets on the rear panel, and one on

the front panel. All are functionally interchangeable.

The outlets are regulated, spike-suppressed, and fi l-

tered against RFI with a 3-pole fi lter, making the unit

a full-function power conditioner. The AR-1215 has

no controls except an on-off switch. (The AR-1215J

and AR-2306 also have an output voltage selector

switch.)

Note: The AR-1215 and AR-2306 are for use with

AC voltage only. DC voltages should never be ap-

plied to them. Also, they do not change or regulate

line frequency. The output frequency will always be

the same as the incoming frequency.

MAXIMUM AND MINIMUM LOAD

The AR-1215 and AR-1215J can handle loads total-

ling up to 15 amperes as long as the input voltage

is equal to or above 124 volts (or 104 volts if using

AR-1215J set to 100 volt output). For voltages below

that level, its capacity must be derated at approxi-

mately 113 milliamperes per volt. (See graphs on

back page.) As a practical matter, therefore, to cope

successfully with worst-case brownout conditions,

you should plan your total load so that it does not

exceed 12 amps, or 1400 watts. Please note that

this refers to the aggregate power requirement of all

equipment plugged into the Voltage Regulator, not to

each individual item.

The AR-2306 can handle loads totalling up to 6

amperes as long as the input voltage is equal to

or above the selected output voltage. For voltages

below that level, its capacity must be derated at ap-

proximately 23 milliamperes per volt. (Again, please

see graphs on back page.) As a practical matter,

therefore, to cope successfully with worst-case

brownout conditions, you should plan your total load

so that it does not exceed 5 amps, or 1100 watts.

Please note that this refers to the aggregate power

requirement of all equipment plugged into the Volt-

age Regulator, not to each individual item.
NOTE: While there is no minimum load require-

ment for the AR1215 or AR-2306, you may

experience an audible mechanical hum coming

directly from the unit when the POWER switch

is on with nothing plugged in. This effect will

disappear as soon as you plug in any equipment

A.C. LINE VOLTAGE�

REGULATOR�

MODEL AR-1215 �

INPUT VOLTAGE�

IN�

REGULATION�

EXTREME �

VOLTAG�E�

SHUTDOWN �

REGULATED OUTLET�

POWER�

ON�

OF�F�

75-98�

� �

W�

A�

R�

N�

I�

N�

G�

FOR CONTINUED �

PROTECTION AGAINST�

FIRE HAZARD REPLACE�

WITH SAME TYPE AND�

RATING OF FUSE�

15 AMP�

100 �V� 120 �V�

75-140 VAC�

REGULATED�

OUTPUTS�

120 VAC�
15 AMPS�

ATTENTION:�

REMPLACER LE FUSIBL�

E�

AVEC MEME TYPE�

DISCONNECT SUPPLY �

BEFORE CHANGING FUSE.�

COUPER L'ALIMENTATION �

AVANT DE CHANGER LE FUSIBL�

E�

6�

A�

M�

P�

220�

OUTPUT VOLTAGE�

230� 240�

CIRCUI� T�

BREAKER�

N’OUVREZ PAS—RISQUE�

DE CHOC ELECTRIQUE�

174-288 VAC 6 � A�

15�

A�

M�

P�

110� 115� 120� 125� 131� 137� 140-150�

105�

101�

15A 120V 50-60HZ�

AR-1215 front view

AR-1215J rear view (the switch above the AC cord is not present in the AR-1215)

AR-2306 rear view. NOTE: The three models in the AR-Series differ in their nominal AC output voltages. Model AR-1215

produces 120 VAC: AR-1215J produces either 100 or 120 VAC; and AR-2306 produces either 220, 230, or 240 VAC.

3