NOTES ON USE
• Take account of common impedance when designing the earth line on a printed wiring board.
• Take measures against static electricity.
- For semiconductors, use antistatic or conductive containers.
- When storing or carrying a printed circuit board after chip mounting, put it in a conductive bag or container.
- The work table, tools and measuring instruments must be grounded.
- The worker must put on a grounding device containing 250 k
Ω
to 1 M
Ω
resistors in series.
• Do not apply a negative voltage
- Applying a negative voltage of
−
0.3 V or less to an LSI may generate a parasitic transistor, resulting in
malfunction.
■
■
■
■
ORDERING INFORMATION
Part number
Package
Remarks
MB3773P
8-pin plastic DIP
(DIP-8P-M01)
MB3773PS
8-pin plastic SIP
(SIP-8P-M03)
MB3773PF
8-pin plastic SOP
(FPT-8P-M01)