Dimensions and clearances
Entire front of icemaker must be clear of obstructions/connections to allow removal.
1" (26mm) clearance above icemaker for service.
1" (26mm) minimum clearance on sides.
The intake and exhaust air grilles must provide at least 150 sq in (968 sq cm) of open area.
Air-cooled model HCE1000A icemakers – 18" (458mm) minimum clearance between discharge and air
intake-grilles.
Cord only
Front View
Side View
Back View
Air exhaust
Air intake
3/8" OD push-in water inlet
1/4" FPT
condenser inlet
1/4" FPT
condenser drain
3/4" MPT drain
Ice transport hose connection
26.63" (677mm)
2.43" (62mm)
2.53
(65mm)
6.95"
(177mm)
14.47"
(368mm)
Air exhaust
both sides
21.05" (535mm)
23.50"
(597mm)
21.28" (541mm)
1.75" (45mm)
min. req'd
22.8" (580mm)
CAUTION
• Keep ventilation openings in the appliance enclosure or built-in structure, clear of obstruction