Specifications, Electrical, Caution – Follett HCE1000A User Manual
Page 5: Plumbing, Ambient, Heat rejection, Ice production

5
F
C
50
10
60
16
70
21
80
27
90
32
60
16
1024
465
966
439
920
418
888
403
825
375
70
21
937
426
896
407
849
386
832
378
747
339
80
27
878
399
820
372
777
353
730
332
678
308
90
32
800
363
748
340
706
321
663
301
610
277
100
38
727
330
676
307
634
288
576
262
520
236
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C
Air-cooled icemaker capacity/24 hrs.
F
C
50
10
60
16
70
21
80
27
90
32
50
10
791
359
762
346
734
333
674
306
645
341
60
16
791
359
762
346
734
333
674
306
645
341
70
21
791
359
762
346
734
333
674
306
645
341
80
27
791
359
762
346
734
333
674
306
645
341
90
32
791
359
762
346
734
333
674
306
645
341
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Water-cooled icemaker capacity/24 hrs.
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C
Specifications
Electrical
Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 220-240/50/1
Maximum icemaker fuse – 15 amps
Amperage – 11 amps
Maximum power – 3600 watts
Climatic class – N
6 ft (2m) cord provided on icemaker
CAUTION
• Plug must be provided by the end-user and must conform to standard EN 60 335-2-24:2003 of the end
destination
• If the supply cord is damaged, it must be replaced by the manufacturer or their service agent, or a similarly
qualified technician in order to avoid a hazard
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).
Drain to be hard piped and insulated.
To prevent back flow, do not connect drains.
Separate drains for icemaker and condenser.
Water shut-off recommended within 10 feet (3m).
Follett recommends installation of Follett model 00130286 activated carbon filter
in icemaker inlet water line.
Ambient
Air temperature
100˚F/38˚C max.
50˚F/10˚C min.
Water temperature
90˚F/32˚C max.
45˚F/7˚C min.
Water pressure – potable
70 psi max. (483 kPa)
10 psi min. (69 kPa)
Note: Water-cooled condenser pressure 150 psi max (1034kPa); 10 psi min (69kPa)
Heat rejection
Air-cooled rejects 10,500 BTU/hr to air (2646Kcal/hr) to air
Water-cooled rejects 10,500 BTU/hr to water (2646Kcal/hr) to water
Ice production