Specifications, Electrical, Caution – Follett HCE1000A User Manual

Page 5: Plumbing, Ambient, Heat rejection, Ice production

background image

5

F

C

50

10

60

16

70

21

80

27

90

32

60

16

1024

465

966

439

920

418

888

403

825

375

70

21

937

426

896

407

849

386

832

378

747

339

80

27

878

399

820

372

777

353

730

332

678

308

90

32

800

363

748

340

706

321

663

301

610

277

100

38

727

330

676

307

634

288

576

262

520

236

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C

Air-cooled icemaker capacity/24 hrs.

F

C

50

10

60

16

70

21

80

27

90

32

50

10

791

359

762

346

734

333

674

306

645

341

60

16

791

359

762

346

734

333

674

306

645

341

70

21

791

359

762

346

734

333

674

306

645

341

80

27

791

359

762

346

734

333

674

306

645

341

90

32

791

359

762

346

734

333

674

306

645

341

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Water-cooled icemaker capacity/24 hrs.

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C

Specifications

Electrical

Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 220-240/50/1
Maximum icemaker fuse – 15 amps
Amperage – 11 amps
Maximum power – 3600 watts
Climatic class – N
6 ft (2m) cord provided on icemaker

CAUTION

• Plug must be provided by the end-user and must conform to standard EN 60 335-2-24:2003 of the end

destination

• If the supply cord is damaged, it must be replaced by the manufacturer or their service agent, or a similarly

qualified technician in order to avoid a hazard

Plumbing

3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)

Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).

Drain to be hard piped and insulated.

To prevent back flow, do not connect drains.

Separate drains for icemaker and condenser.

Water shut-off recommended within 10 feet (3m).

Follett recommends installation of Follett model 00130286 activated carbon filter

in icemaker inlet water line.

Ambient

Air temperature

100˚F/38˚C max.

50˚F/10˚C min.

Water temperature

90˚F/32˚C max.

45˚F/7˚C min.

Water pressure – potable

70 psi max. (483 kPa)

10 psi min. (69 kPa)

Note: Water-cooled condenser pressure 150 psi max (1034kPa); 10 psi min (69kPa)

Heat rejection

Air-cooled rejects 10,500 BTU/hr to air (2646Kcal/hr) to air
Water-cooled rejects 10,500 BTU/hr to water (2646Kcal/hr) to water

Ice production