beautypg.com

Field Controls UV-AIRE UV-1500C User Manual

Page 2

background image

page 2

WARNING:

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire

®

Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.

Model

Volts Amps Hz Watts Lamp Intensity at

1 meter

Recommended

Max. Sq. Feet

Weight

Width

(Inches)

Height

(Inches)

Depth

(Inches)

UV-1500C

120

1.3

60

130

37µW/cm

2

1500

15.5 lbs

18

23-

3

4

6-

5

16

INDICATION FOR USE

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or

condition nor for use in the mitigation, treatment, or prevention of any disease or condition.

GENERAL INFORMATION

WARNING:

This product is designed for indoor installation only.

The UV-1500C is designed as a multipurpose room air purification system. The unit can be placed in a room

sitting on the floor, it can be mounted on the wall to maximize floor space, or it can be mounted into a

suspension (drop) ceiling.

FEATURES

The UV-1500C is equipped with a speed control to allow the user to adjust the airflow through the unit

1.

from 35 cfm to 100 cfm.
The UV-1500C has a safety shut off switch that disconnects power to the fan and the lamp if the front

2.

access door is opened.
The UV-1500C is equipped with a circuit board to monitor the operation of the UV lamp; it indicates the

3.

operation of the lamp through an LED indicator light mounted on the front access door. The circuit board

indicates good operation of the lamp by a continuous “GREEN” color on the LED light. After 8320

hrs of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous

“YELLOW” color on the LED light and the internal alarm will beep every 15 minutes. After 9000 hrs of

lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “RED”

color on the LED light and the internal alarm will beep every 5 minutes. The board also checks if the UV

lamp is burned out. The circuit board will indicate this by a continuous “RED” color on the LED and the

internal alarm will beep every 5 minutes.

UV-1500C CHECK OUT PROCEDURE

Plug the power cord into a standard 120-volt wall receptacle.

1.

Turn the speed control knob clockwise to turn the unit on. After the fan has started, the LED light will

2.

show a continuous “GREEN” color indicating proper unit operation.
Once you have determined that the unit is functioning properly, turn unit off and unplug.

3.

Continue to next section for mounting options.

4.