5
Specifications
Electrical
Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 208-230/60/1
Maximum icemaker fuse – 15 amps each
Amperage – 11 amps
6 ft (2m) NEMA 6-15 cord and plug provided on icemaker
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).
Drain to be hard piped and insulated.
To prevent back flow, do not connect drains.
Separate drains for icemaker and condenser.
Water shut-off recommended within 10 feet (3m).
Follett recommends installation of Follett water filter system (part# 00130286) in icemaker
inlet water line.
Ambient
Air temperature
100˚F/38˚C max.
50˚F/10˚C min.
Water temperature
90˚F/32˚C max.
45˚F/7˚C min.
Water pressure – potable
70 psi max. (483 kPa)
10 psi min. (89 kPa)
Note: Water-cooled condenser pressure 150 psi (1034 kPa)
Heat rejection
Air-cooled rejects 11,300 BTU/hr
Water-cooled rejects 12,800 BTU/hr
Ice production
F
C
50
10
60
16
70
21
80
27
90
32
60
16
1135
515
1070
486
1015
461
967
439
924
420
70
21
1100
499
1000
454
938
426
902
410
859
390
80
27
962
437
916
416
871
395
826
375
782
355
90
32
828
376
816
371
794
361
755
343
698
317
100
38
786
357
728
331
686
312
654
297
610
277
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C
Air-cooled icemaker capacity/24 hrs.
F
C
50
10
60
16
70
21
80
27
90
32
60
16
1071
486
1025
465
971
441
912
414
849
386
70
21
1035
470
979
444
932
423
888
403
842
382
80
27
975
443
912
414
870
395
839
381
814
370
90
32
885
402
826
375
786
357
759
345
745
338
100
38
762
346
723
328
683
310
642
292
603
274
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Water-cooled icemaker capacity/24 hrs.
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C