Fig. 22
11. Reconnect transport tube to louvered
docking assembly.
12. Plug sensor in at the electrical box.
13. Reconnect vent tube to the shuttle housing 
as shown.
Apply
petrol-gel
Fig. 23
14. Apply a coat of petrol-gel to the auger shaft.
15. Install gearmotor, making sure that insulation is 
properly seated between gearmotor and main 
housing as shown.
16. Firmly tighten four gearmotor bolts in place.
removed for clarity
Note: Shuttle housing
Fig. 21
6. Orient auger shaft with keyway in the
upward position.
7. Force main housing into position against evaporator
and place 1/4" (7mm) diameter Phillips screwdriver 
into hole in the auger shaft.
8. Replace V-band clamp as shown.
9. Replace nut on V-band clamp and tighten.