6.4.5
Operation error
This response indicates that the error related to operation specification program
occurs.
Byte 1
CNT
Byte 2
RPS
Byte 3
TEXT
X©03π
X©55π
Detailed error information I
Detailed information I
Detailed information I gives details on errors in command/response transmission
and reception to and from the host computer.
7
6
5
4
3
2
1
0
0
0
LSB
The dither pattern or the overlay pattern r pattern
not registered was specified.
The bit or number of an undefined control register
was specified.
An operation was specified for a nonexistent
option.
Read area specification error (*1)
An undefined command was received.
Command sequence error
MSB
*1 Although standard paper size bit on control register 5 is on (Bit 7 takes ™1∫ and
bit 6 takes ™0∫), the size specifying bits (bits 0 to 4) are not defined.
Control register contents do not change even if the above errors are detected.
6 $ 60