Installation instructions, Electrical connection requirements, Location – FRIGIDAIRE 318200439 User Manual
Page 5: Circuit protection (models with electric oulet(s))
5
Installation Instructions
Installation and service must be performed by a qualified technician.
* 76.2 cm (30”) Minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal
cabinet; or 61 cm (24”) Minimum when bottom of wood or metal cabinet is protected by not less than 0.64 cm (1/4”) flame
retardant millboard covered with not less than 0.038 cm (0.015”) stainless steel, 0.061 cm (0.024”) aluminum or 0.051 cm
(0.020”) copper. 1.3 cm (1/2”) clearance is the minimum for the rear and sides of the range. Follow all dimension requirements
provided above to prevent property damage, Potential fire hazard, and incorrect countertop and cabinet cuts.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 12.7 cm (5”) beyond the bottom of the cabinets.
Electrical Connection Requirements
Plug the range cable (4 conductors) into a 4 conductor range outlet. Outlet must be
properly grounded and in accordance with the Canadian Electrical Code (CSA Stan-
dard (C22.1 Part 1 -- latest edition) -- and any local electrical code requirements.
Location
Set your new range 1.3 cm (1/2”) away from the rear wall and line it up with the kitchen
counters. Make sure there is at least 1.3 cm (1/2”) of clearance between each side of
the range and the kitchen counters. Allow 7.6 cm (3”) min. clearance between your
range and the refrigerator, if they are side by side.
Circuit Protection (Models with electric oulet(s))
As a protection against surcharge, a 15 amp, 120 volt breaker is provided for each of the electric outlet(s) (2 max.) located on
top or underneath of the control panel. Models with no electric outlet have no breaker.
A
76.2 cm (30”)
A
66 cm (26”)
91.4 ± 0.3 cm
(36 ± 1/8”)
122 cm (48”)
Maximum
114.3 cm (45”)
Door Open
DIMENSIONS
B
78.7 cm (31”)
C
76.2 cm (30”)
IMPORTANT: Save for the local electrical inspector’s use.
Read and save these instructions for future reference.
Clearances and Dimensions
a. Provide adequate clearances between the range and adjacent combustible surface (1.3cm (1/2”) to the cabinet side walls
and the rear wall).
b. Location—Check location where the range will be installed. Check for proper electrical supply and the stability of floor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid
and level.
45.7 cm
(18”)
C
*
76.2 cm (30”)
Minimum
Minimum to
wall on either
side of range.
91.4 cm
(36”)
B
SIDE
VIEW
FRONT
VIEW
Minimum to
cabinets on
either side of
range.
Maximum depth for
cabinets above
range top.
33 cm
(13”)
1.3 cm
(1/2”)