Frymaster BIPH14 series User Manual
Page 5
1-1
BIPH14/MPH14 SERIES ELECTRIC FRYERS
CHAPTER 1: SERVICE PROCEDURES
1.1 General
Before performing any maintenance on your Frymaster fryer, disconnect the fryer from the electrical
power supply.
To ensure the safe and efficient operation of the fryer and hood, the electrical plug for the 120-volt
line, which powers the hood, must be fully engaged and locked in its pin and sleeve socket.
When electrical wires are disconnected, it is recommended that they be marked in such a way as to
facilitate re-assembly.
1.2 Replacing a Computer
1. Before removing controllers from Euro-look models (round top-cap and drains), slide the metal
bezel up to release the bottom tabs; then, remove it.
2. Remove the two screws from the upper corners of the control panel. The control panel is hinged
at the bottom and will swing open from the top.
Remove screws in upper
corners of control panel and
swing control panel down.
3. Unplug the wiring harness from the connector on the back of the computer and disconnect the
grounding wire from terminal adjacent to the connector. Remove the control panel assembly by
lifting it from the hinged slots in the control panel frame.
Ground Wire Terminal
15-Pin Connector