Frymaster SinBaD Series User Manual
Page 10
2-5
If the dispensing chute does not fill within 30 seconds, the CHECK HOPPER indicator
in the
middle of the control panel will begin to blink and drum rotation will stop. Check the hopper to see if
it is empty. If it is empty, reload the hopper then press the PROGRAM Switch once to place the unit
back into operation. If the hopper appears to contain plenty of fries, the fries have probably “bridged”
(i.e., stuck together to form an arch over the drum). Redistribute the fries then press the PROGRAM
Switch once to place the unit back into operation.
2.4 Manual
Operation
If the unit fails to zero, the unit can be manually operated until a servicer arrives to make repairs. Follow the
procedure below.
1. Turn the computer off (press the RUN Switch ).
2. Place a basket under the hopper dispense door.
3. Press the CLEAN Switch once to dispense fries into the basket. NOTE: If the dispense door fails to
open, pull down on the door arm to manually open the door.
4. When the basket is filled to the desired level, press the CLEAN Switch once to stop dispensing fries.