Field Controls UV-12 User Manual
Page 6
![background image](/manuals/102973/6/background.png)
page 6
WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Replace cover on unit. Tighten side screws. (See Figures 19 & 20)
11.
Plug the power cord into a standard electrical outlet.
12.
NOTE:
Seal the joints and seams of the plenum near the mounting
location to reduce any direct viewing of light. (See Figure 1)
Flip switch on box to the ON position. (Light on switch should be
13.
on, indicating power.)
Look through view port in the box cover to be sure lamp is working. You should
14.
see a blue glow. (The view port is covered with a plastic lens that blocks the
UV-C rays.)
If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow,
15.
contact technical support at 1-252-522-3031 for further assistance.
Figure 20
Figure 19
BULB MOUNTING BRACKET SELECTION AND INSTALLATION
The UV-Aire units come with an angled mounting bracket and flat mounting bracket to position the bulb
either straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to
the configurations chart below when making your selection.
UV-Aire Configurations
Good
Standard 90º Installation
Flat Bracket (16” Duct)
Best
Patent Pending 45º Installation
Single Lamp Angle Bracket (16” Duct)