STEP 4 CHECKING WIRING AND PLUMBING: Check all wiring and

plumbing inside and outside of the wall to be sure none will be

broken where the hole is to be cut.

STEP 5 HOLE CONSTRUCTION: Depending upon size of unit to be

installed, lay out the hole dimensions per the chart below. Cut

and frame in hole to finished dimensions. Use 2" x 4" material for

framing and follow the suggested typical installations in Figure

C, D, or E.

NOTE: IF THE WALL CONSTRUCTION IS TYPICAL FRAME

OR 2 x 4 STUDDING WITH BRICK OR STONE VENEERS,

LOCATE THE HOLE NEXT TO ONE OF THE STUDS. FOR

MASONRY, CONCRETE OR CINDER BLOCK WALLS,

LOCATE HOLE FOR CONVENIENCE.

NOTE: THESE DIMENSIONS ARE FOR FINISHED HOLE SIZE.

FINISHED

DIMENSION

SMALL

CHASSIS

MEDIUM

CHASSIS

LARGE

CHASSIS

A

16

3

16

"

18

3

16

"

20

3

8

"

B

26

3

16

"

26

3

16

"

28

1

4

"

CABINET

CAULK ALL SIDES

ELECTRICAL

RECEPTACLE

(SEE FIG. E FOR

LOCATION NOTE)

SHIM THE VOID

SPACE AT THE

TOP AND SIDES

WITH WOOD AS

REQUIRED

Figure C
FRAME WALL CONSTRUCTION

CAULK ALL SIDES

CABINET

SHIM VOID SPACES AT TOP AND

SIDES WITH WOOD AS REQUIRED

ELECTRICAL RECEPTACLE

(SEE FIGURE E FOR

LOCATION NOTE)

Figure D
BRICK VENEER CONSTRUCTION

MORTAR

ELECTRICAL

RECEPTACLE

POINT "X"

CABINET

CAULK

ALL SIDES

Figure E
SOLID MASONRY CONSTRUCTION

NOTE: ELECTRICAL RECEPTACLE LOCATION FROM

POINT "X" MUST BE WITHIN A MAXIMUM RADIUS OF

69" FOR 115V UNITS AND 45" FOR 230V UNITS.