P53

Hold Temp Std
The standard temperature, which the air probe must read before the condensing system is de-energised in the
Hold mode of the Professional 3 Program.
Range -15°C to 15°C.

P54 Hold

Temp

Minimum

The minimum value that the Hold temperature set point can be adjusted to by the operator in the Professional 3
program.
Range -10°C to 0°C.

P55 Hold

Temp

Maximum

The maximum value that the Hold temperature set point can be adjusted to by the operator in the Professional 3
program.
Range 0°C to 10°C.

P56 Change

Time

The percentage period of a time based chill cycle, which is to have passed before automatically adjusting the air
temperature set point to 1°C.The range is adjustable in 5% increments.

Range 05% to 95%.

P5

The percentage of a temperature based chill cycle, which is passed before automatically adjusting the air
temperature set point to 1°C.The range is adjustable in 5% increments.

7 Change

Temp

Range 5% to 95%.

System
P58

UV Light Enable

Determines whether the user can select the UV sanitisation.

Minutes 0 = disabled, 1 to 120 = enabled (set the time between 1 and 120 to determine the length of the
program).

P59 HACCP

Enable

Determines whether the logging system is available to the user.

Function, YES = enabled. NO = disabled.

P60

Shock Freeze Temp

Allows for the probe to be used in the Shock Freeze mode.
Function, YES = enables. NO = disables.

P61 Chill

Hysteresis

Allowable temperature increase from chill cycle air temperature Set Point before switching on the refrigeration
system.

Range 02°K to 20°K.

P62 Hold

Hysteresis

Allowable temperature increase from hold cycle air temperature Set Point before switching on the refrigeration
system.

Range 02°K to 20°K.


P63 APM

Time

Automatic Program Mode Time. The time period that must pass before the air temperature and Food Probe 1
temperature are compared to determine whether the cycle is time or temperature based.

00 = Instantaneous decision. 01 to 30 = the time selected determines the start time decision.

P64 APM

Differential

Automatic Program Mode Differential. The difference in temperature between the air temperature and food probe
1 temperature after APM time to determine whether the cycle is time or temperature based. If air probe
temperature + the APM differential is greater than or equal to food temperature the chill cycle will be time based.
If air probe temperature + APM differential is less than the food probe temperature the chill cycle will be
temperature based.
Range 0°K to 20°K.

P65

FAN 1 Hold Operation

Determines the evaporator fan relay energisation during ‘Hold’ mode.

‘OFF’

= Evaporator fan 1 relay is not energised in ‘Hold’.

‘CYCLE’

= Evaporator fan 1 relay cycles with condensing system relay in ‘Hold’.

‘AUTO’

= Evaporator fan 1 relay cycles with condensing system and fan hysteresis in ‘Hold’.

‘ON’

= Evaporator fan 1 relay is always energised in ‘Hold’.