Fre sh – Field Controls IAQ11 User Manual
Page 7
FRE
SH
fieldcontrols.com
7
FRE
SH
Automatically opens to allow fresh
air inside return duct
FRESH AIR/MAKE-UP DAMPER (MAS)
Air from all rooms
RETURN
FRESH
The Healthy Home System™ Control
intelligently manages the central fan,
allowing the Fresh Air Damper to provide
FRESH
air in the home all year round...
even when not heating or cooling.
How It Works
The FAD is a motor driven damper activated by the Healthy
Home System Control. When there is a call for fresh air, the
HHSC opens the damper allowing fresh air to enter the HVAC
return. When the HHSC is satisfied, the damper is closed.
Fresh Air Dampers
Features
• Adjustable gate provides precise air flow control
• Easy to read air flow gauge
• No electricity required
• 24 gauge aluminum coated steel
• Corrosion resistant and paintable
• Intake air hood included
• Quiet operation
MAS –
Pressure Activated Damper
How It Works
The MAS is a pressure activated damper that opens whenever
the central fan is on. It closes automatically when the fan is
turned off. The adjustable gate provides precise control of air
flow based on the needs of the structure.
Features
• Durable, stainless steel construction
• Motor-driven damper
• Controlled by HHSC
• Energy efficient operation
• Reliable, proven design
• Remains closed when fresh air is not needed
FRESH AIR DAMPER (FAD)
Air from all rooms
RETURN
Allows fresh air flow when activated
by the Healthy Home System™ Control
FAD –
Motorized Damper
7