8. Operator Troubleshooting Guide

Symptom Possible

Cause

No computer display; no flow from
air tower

No power

Circuit breaker out
Low voltage
Bad fuse
Bad transformer
Hi-limit out

No flow from air tower

Bad latching relay

After 20 minutes of operation
computer display shows PROB

RTD probe has failed. Isolate failed
component by checking temperature of
air and heater plate with the temperature
display keys on the computer. The plate
temperature should be within ± 15°F of
setpoint. The air heat should be within ±
25°F of setpoint. If both temperatures are
good, the computer is likely bad.

After 20 minutes of operation
computer display shows HI

Plate heater, plate heater relay or RTD
are faulty.

After 20 minutes of operation
computer display shows LO

Air heater, air heater relay or RTD are
faulty