beautypg.com

Cleaning and maintenance – FMI BVC-50Y User Manual

Page 33

background image

www.fmiproducts.com

122280-01E

33

CLEanInG anD MaIntEnanCE

WARNING: Installation and

repair should be done by a quali-

fied service person. The appli-

ance should be inspected before

each use and at least annually

by a qualified service person.

More frequent cleaning may be

required due to excessive lint

from carpeting, bedding mate-

rial, pet hair, etc. It is imperative

that the control compartments,

burners and circulating air sys-

tem be kept clean.

WARNING: The logs can be

hot. Handle only when cool.

WARNING: Turn off gas and

electrical power before servicing

appliance.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

GLASS DOORS

Glass doors are optional with the fireplace.

When fireplace is in operation, doors must be

fully opened or fully closed position only or a

fire hazard may be created (see Figure 41).
A fireplace equipped with glass doors oper-

ates much differently than a fireplace with an

open front. A fireplace with glass doors has a

limited amount of air for combustion.
Excessive heat within fireplace can result if

too large a fire is built or if combustion air

gate is not completely open. The following tips

should be followed to assure that both fire-

place and glass doors retain their beauty and

function properly. Both flue damper and glass

doors must be fully opened before starting fire.

This will provide sufficient combustion air and

maintain safe temperatures in firebox.

WARNING: Fireplaces

equipped with glass doors

should be operated only with

doors fully opened or doors fully

closed. Doors, if left partly open,

may draw gas and flame out of

the fireplace opening creating

risks of both fire and smoke.

CLEANING GLASS

Clean glass with any commercial glass

cleaner or soap and water. Do not use any

abrasive material to clean glass. Do not clean

glass with any cool water if glass is still hot

from the fire and smoke.
A gas line or gas log lighter may be installed

for the purpose of installing a vented or vent-

free decorative gas appliance incorporating an

automatic shutoff device and complying with

the Standard for Decorative Gas Appliances

for Installation in Vented Fireplaces, ANSI

Z21.60 or American Gas Association draft

requirements for Gas Fired Log Lighters for

Wood Burning Fireplaces, Draft NO. 4 dated

August, 1993.

Figure 41 - Bi-Fold Glass Doors

Doors Fully Closed

Fireplace Front

Doors

Fully Opened

Fireplace Front

This manual is related to the following products: