beautypg.com

Owner’s manual, Product identification local codes, Safety information – FMI VFP24R User Manual

Page 3: Product features, Unpacking

background image

3

105073

OWNER’S MANUAL

Figure 1 - Ember Master

Front
Logs

Control Knob

Rear Log

Base
Assembly

Front
Burner

Piezo
Ignitor

Rear
Burner

Crossover Log

Bottom
Middle
Log

Selector Switch
(Optional)

Flame
Adjustment
Knob

PRODUCT
IDENTIFICATION

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANS Z223.1
, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

Batterymarch Park

New York, NY 10018

National Fire Protection Association, Inc.

1430 Broadway

Quincy, MA 02269

Note:

Where listed vented decorative logs

are required, thermostat operation is not
permitted.

14. Do not operate heater if any log is bro-

ken. Do not operate heater if a log is
chipped (dime-sized or larger).

15. Turn heater off and let cool before ser-

vicing, installing, or repairing. When
using the hand-held remote accessory,
make sure the selector switch is in the
OFF position. Only a qualified service
person should install, service, or repair
heater.

16. When using the hand-held remote acces-

sory, make sure the selector switch is in
the OFF position when you are away
from home for long periods of time.

17. This heater must not be connected to

any external electrical source.

18. Operating heater above elevations of

4,500 feet may cause pilot outage.

19. To prevent performance problems, the

use of a propane/LP fuel tank of less than
100 lb. capacity is not recommended.

SAFETY
INFORMATION

Continued

PRODUCT
FEATURES

OPERATION

This heater is clean burning. It requires no
outside venting. There is no heat loss out a vent
or up a chimney. Heat is generated by both
realistic flames and glowing coals. This heater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANS Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free heat-
ers. This heater may also be operated as a
vented decorative (ANS Z21.60) product by
opening the flue damper (non-thermostat
operation only).

SAFETY PILOT

This heater has a pilot with an Oxygen
Depletion Sensing(ODS) safety shutoff sys-
tem. The ODS/pilot is a required feature for
vent-free room heaters. The ODS/pilot shuts
off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.

Top Middle Log

UNPACKING

CAUTION: Do not remove the

metal data plates from the grate
assembly. The dataplates contain
important product information.

1.

Remove logs and heater base assem-
bly from carton.

Note:

Do not pick up

heater base assembly by the burner.
This could damage heater. Always
handle base assembly by grate.

2.

Remove all protective packaging ap-
plied to logs and heater for shipment.

3.

Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.

Continued