WARNING:

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire

®

Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.

BULB MOUNTING BRACKET SELECTION AND INSTALLATION

The UV-Aire units come with an angled mounting bracket and flat mounting bracket to

position the bulb either straight or at an angle. Choose the bracket method best suited for

your needs. Refer to the configurations chart below when making your selection.

Replace cover on unit. Tighten side screws. (See Figure 19 & 20)

11.

Plug the power cord into a standard electrical outlet.

12.

NOTE: Seal the joints and seams of the plenum near the mounting location to
reduce any direct viewing of light.
(See Figure 1)

Flip switch on box to the ‘ON’ position. (Light on switch should be on indicating

13.

power.)

Look through view port in the box cover to be sure lamp is working. You should

14.

see a blue glow. (The view port is covered with a plastic lens that blocks the
UVC rays.)

If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact

15.

technical support at 1-252-522-3031 for further assistance.

Figure 20

Figure 19