Figure 49. j11 connections, Table 23. j11 connections – Fusion F300S User Manual
Page 120

120
F300S/F300SQ Ultraviolet Lamp System
Figure 49. J11 Connections
8. Connect the replacement J11 connector to the chassis.
The black and white leads
from the blower motor have pins installed; these pins must be inserted into the
back of J11 as indicated in
9. Connect the ring terminals on the green/yellow wire from J11 and the
green/yellow wire from the blower to the ground screw.
10. Connect the push-on terminals to capacitor C200.
11. Reinstall the blower housing cover plate and the blower cover.
Table 23. J11 Connections
J11-1
Green/Yellow
J11-2
Black
J11-3
White
1
2
3
4
This manual is related to the following products: