beautypg.com

Rotary field indication, Measurement point illumination – Fluke Fiber Viewer FT140 User Manual

Page 10

background image

Rotary Field Indication

The voltage testers are equipped with a double-

pole rotary field indicator.

The safety measures have to be met

The rotary phase indication is always active.

The symbols R

or

L are always displayed.

However, the rotary direction can only be deter-

mined within a three-phase system. Here, the

instrument indicates the voltage between two

external conductors.

• Connect the instrument test probe with the

supposed phase L2 and the handle test

probe with the supposed phase L1.

• Touch Accessible electrode (11).

The voltage and the rotary field direction are

displayed.

signifies that the supposed phase L1 is

the actual phase L1 and the supposed

phase L2 is the actual phase L2

==> right rotary field

signifies that the supposed phase L1 is

the actual phase L2 and the supposed

phase L2 is the actual phase L1

==> left rotary field.

When re-testing with exchanged test pro-

bes the opposite symbol has to be illumi-

nated.

Measurement Point Illumination

Voltage testers T100re equipped with a measu-

rement point illumination feature. Thus, working

under bad lighting conditions (e.g. division

switch cabinets) is made easier.

• Press button for measurement point illuminati-

on (10) on instrument rear.

L

R

L1

L2

L3

N

PE

L

L1

L2

L3

N

PE

R

Fluke T100/120/140
Users Manual

10

This manual is related to the following products: