DECATHLON SERIES GAS FRYERS (CE)

CHAPTER 3: INSTALLATION

3-3

3.4 Gas Categories

Installation shall be made with a gas connector that complies with national and local codes.

Quick disconnect devices, if used, shall likewise comply with national and local codes.


WARNING

The fryer

MUST be connected to the gas supply specified on the rating and serial

number plate located on the back of the fryer door.


WARNING

If gas odors are detected, the gas supply

MUST be shut off at the main shut-off

valve. The local gas company or FASC should be contacted immediately to rectify

the problem.


Dean Decathlon Series gas fryers have obtained CE markings for countries and gas categories listed
in the table below:

Countries

Supply Pressures and
Gas (mbar)

Appliance
Categories

Countries

Supply Pressures and
Gas (mbar)

Appliance
Categories

G20

20/25

I2E (R) B

G20

20

BE Belgium

G31

37

I3P

GR Greece

G31

37 and 50

II2H3P

G20

20

I2E

G20

20

DE Germany

G31

50

I3P

IR

Ireland

G31

37

II2H3P

DK Denmark

G20

20

I2H

IT

Italy

G20

20

I2H

G20

20

G20/G25

20/25

ES

Spain

G31

37 and 50

II2H3P

LU Luxembourg

G31

50

II2E3P

G20/G25

20/25

G25

25

FR France

G31

37 and 50

II2ESI3P

NL

The
Netherlands

G31

50

II2L3P

G20

20

G20

20

GB Great Britain

G31

37

II2H3P

PT

Portugal

G31

37

II2H3P