Furuno FR-7112 User Manual
Page 48
SP - 4
XN13A(24rpm): 80 W to 120 W(100 kt)
FR-7112
XN12A(24rpm): 85 W to 100 W(100 kt)
XN12A(48rpm): 95 W to 120 W(70 kt)
XN13A(24rpm): 90 W to 130 W(100 kt)
FR-7252
XN12A(24rpm): 105 W to 125 W(100 kt)
XN12A(48rpm): 120 W to 140 W(70 kt)
XN13A(24rpm): 115 W to 150 W(100 kt)
7. DIMENSIONS AND MASS
See Outline Drawings
8. CORTING COLOR
(1) Display Unit
Panel: N3.0
Chassis: 2.5GY5/1.5
(2) Scanner Unit
N9.5
9. COMPASS SAFE DISTANCE
(1) Display Unit
Standard: 1.1 m
Steering: 0.8 m
(2) Scanner Unit
FR-7062/7112
Standard: 1.0 m
Steering: 0.8 m
FR-7252
Standard: 1.7 m
Steering: 1.3 m
10. ARP MODULE (OPTION)
(1) Acquisition Range
0.2 to 16 NM
(2) Tracking Range
0.1 to 16 NM
(3) Maximum Number of Target 10
(4) Acquisition Time
Within 5 sec (scanner rotation: 24 rpm)
(5) Alarm Timing
Lost target (blink mark, collision alert)
(6) Vector Length
30 sec; 1, 3, 6, 15 or 30 min (selected on menu)
(7) Plotting Interval
15, 30 sec; 1, 2, 3 or 6 min (selected on menu)
(8) Numeric Data Indication
Distance, Bearing, Course, Speed, CPA, TCPA
(9) Acquisition Available Speed 100 kt relative