Replacement parts, Models & specifications – Field Controls Solution For Great Indoors 24v User Manual
Page 12
©2007 Field Controls
form# 4283
Printed in U.S.A.(CP07)
Field Controls, LLC | www.fieldcontrols.com | 2630 Airport Road | Kinston, NC 28504 | TEL: 252.522.3031 | FAX: 252.522.0214
www.fieldcontrols.com
Replacement Parts
Model
Minimum
Duct Width
Voltage
Amps
Hz
Watts
Circuit
Board
Recommended
Max. Sq. Ft.
Lamp Intensity at
1 meter µW/cm
2
Product
Warranty
UV-12
9
120
0.5
60
30
no
1500
37
5 yr
UV-18
14
120
0.5
60
30
no
2000
73
5 yr
UV-28
22
120
1.1
60
60
no
3000
105
5 yr
UV-12E**
9
120/208/240 0.5
60
30
no
1500
37
5 yr
UV-18E**
14
120/208/240 0.5
60
30
no
2000
73
5 yr
UV-28E**
22
120/208/240 1.1
60
60
no
3000
105
5 yr
UV-12HP
9
240
0.5
60
30
no
1500
37
5 yr
UV-18HP
14
240
0.5
60
30
no
2000
73
5 yr
UV-28HP
22
240
1.1
60
60
no
3000
105
5 yr
UV-12C
9
120
0.5
60
30
yes
1500
37
1 yr
UV-18C
14
120
0.5
60
30
yes
2000
73
1 yr
UV-28C
22
120
1.1
60
60
yes
3000
105
1 yr
UV-12HPC
9
240
0.5
60
30
yes
1500
37
1 yr
UV-18HPC
14
240
0.5
60
30
yes
2000
73
1 yr
UV-28HPC
22
240
1.1
60
60
yes
3000
105
1 yr
UV-18X*
14
120
1.0
60
60
no
4000
2@73
5 yr
UV-500C
NA
120
0.4
60
36
yes
500
24
1 yr
UV-1500C
NA
120
0.5
60
30
yes
1500
37
1 yr
UV-16/120
16
120
0.5
60
30
no
2000
62
5 yr
UV-16/24
16
24
1.3
60
30
no
2000
62
5 yr
EL-1***
Fits any crawl
space vent
120
0.6
60
35
-
1000
-
1 yr
EDH-1***
Humidity
Switch
@120
12
max
-
-
-
-
-
1 yr
*
UV-18X includes two lamps.
**
UV-E series includes aluminum NEMA 3 enclosures for external, outdoor installation.
***
The EL-1 Eliminator and the EDH-1 De-Humidistat are not UV-Aire products but are recommended
to help control and reduce moisture and moisture related problems in crawl spaces.
Note: All lamps are warranted for 90 days after installation. A UV-Aire counter display is
available. For more information, contact Field Controls.
UV-500C Replacement Kit
• 4 high-efficiency/
carbon filters
• 1 UV lamp
UV-1500C Replacement Kit
• 1 carbon filter
• 4 high-efficiency/
carbon filters
• 1 UV lamp
It is important that lamps be replaced when the ultraviolet output falls below minimum requirements for protection.
Even though a lamp will appear to be operating effectively because it still maintains the visible blue glow, the
ultraviolet output will be significantly reduced after 9000 hours of use.
To maintain maximum benefits,
lamps should be replaced annually.
UV-Aire Germicidal Lamps
• 8", 12", 16", 18" and 28"
UV-500C Filter Pack
• 4 high-efficiency/
carbon filters
• A one year supply
UV-1500C Filter Pack
• 1 carbon filter
• 4 high-efficiency/
carbon filters
• A one year supply
UV-500C Replacement Kit
• 4 high-efficiency/
carbon filters
• 1 UV lamp
UV-1500C Replacement Kit
• 1 carbon filter
• 4 high-efficiency/
carbon filters
• 1 UV lamp
NEW