beautypg.com

Cleaning & maintenance, Cleaning venturi tubes, Perform a leak test – Fiesta FG50057 User Manual

Page 7: Warning, How to clean, What you’ll need for testing, How to do the testing

background image

7

Fig. 7C

STANDARD

3 BURNER

Fig. 7D

GAS VALVE

3 BURNER WITH SIDE

BURNER & ROTISSERIE

HOSE &
CONNECTIONS

SIDE BURNER
GAS LINE

REGULATOR

GAS VALVE

GAS REGULATOR

EXTERNAL
THREAD

HAND
VALVE

Fig. 7B

THERMALLY

SENSITIVE

NUT

PROBE

TANK

TANK
WELDS

Fig. 7A

CLEANING VENTURI TUBES

Periodic cleaning of the venturi tubes is recommended
for optimum burner performance, especially after
prolonged storage or a period of non-use.

How to Clean:

• Remove the burner (refer to ‘ASSEMBLY PROCEDURE’).
• Use a venturi cleaning brush and insert the brush into the venturi tube 1

inch at a time, then remove to prevent moving the debris upwards
(see Figure 8).

• As you remove the brush head inspect and discard any debris
• Continue this procedure until the entire lengths of all venturi tubes are

free of debris.

• Reinstall burner (as per assembly instructions), ensure the venturi

tubes are seated over the valve orifices (see Figure 1).

• Perform a Leak Test (see pages 4 & 5).

CHECK TO ENSURE THE BURNER HAS A

GOOD FLAME EACH TIME IT IS TURNED ON.

Fig. 8

VALVE

BLOCKAGE

VENTURI

CLEANING BRUSH

WARNING

It is possible that very small insects could make webs or nest in the venturi tubes, as they are naturally
attracted to the smell of gas. This will partially or completely block the flow of gas through the venturi
and is indicated by a smoky yellow flame, and/or a burner that is difficult or impossible to light.
Ultimately, it may cause the gas to burn outside the venturis, which can cause a fire resulting in

damage to your barbeque and potential personal injury. IF THIS HAPPENS IMMEDIATELY SHUT OFF THE PROPANE AT
CYLINDER. When the barbeque has cooled, follow the "How to Clean" steps above.

WARNING

Failure to ensure the above may result in a

hazardous fire or explosion causing serious

bodily injury and/or property damage.

REGULATOR

HOSE &

CONNECTIONS

To keep your barbeque working at its peak efficiency
as well as contribute to the safe operation of this
unit, perform all of the operations below at least
once a year -- preferably at the start of each cooking
season.

PERFORM A LEAK TEST

A leak test ensures that there are no gas leaks prior to lighting your

barbeque.
WHEN A LEAK TEST MUST BE PERFORMED:
• Before lighting your barbeque for the first time
• Every time the propane cylinder is refilled
• If any gas component is changed
• At a minimum once per season
• After prolonged period of storage or non-us
• If the regulator flow-limiting device has been activated

The leak test should be performed in a well-ventilated area away from any
open flame, heat or ignition sources.
DO NOT USE A MATCH, OPEN FLAME OR SMOKE DURING LEAK TESTING.

WHAT YOU’LL NEED FOR TESTING:

1. A mixture of 50% liquid dish soap and 50% water.
2. A brush or cloth to apply the mixture.
AREAS TO TEST ON A PROPANE BARBEQUE:
• All propane cylinder welds (see Figure 7A)
• Propane cylinder valve – including threads into cylinder (see Figure 7B)
• Regulator fitting and propane cylinder connection (see Figure 7B)
• All hose connections (see Figure 7C) including side burner tubing,

if equipped (see Figure 7D)

• All valve connections (see Figure 7C & D)
AREAS TO TEST ON NATURAL GAS BARBEQUES:
• All hose connections (see Figure 7C)
• All valve connections (see Figure 7C & 7D)

CLEANING & MAINTENANCE

HOW TO DO THE TESTING:

1. With the barbeque console control knobs in the ‘OFF’ position, twist the valve

on your propane cylinder 1 turn, or the main natural gas valve on.
DO NOT IGNITE THE BURNERS WHILE PERFORMING THE LEAK CHECK.

2. Brush your soap and water solution on all connections and components

as outlined above.

3. Observe each place for growing bubbles, which indicate that a leak is present.
4. Shut off the flow of gas while fixing the leak. Tighten any leaking

connection and repeat test until no leaks are detected.

5. If the leak(s) cannot be stopped DO NOT USE. Shut off the fuel source at

the valve immediately (if appropriate, remove propane cylinder). Call a
certified gas appliance service person, or a gas dealer for proper repairs.