SB-1000 MANUAL

INSTALLATION

Inspect the UPS upon receipt. Any damage

to the packaging or unit is not covered under

warranty. Contact your parcel carrier.

1) Recharge the batteries

The UPS may be used immediately upon

receipt. Recharging the batteries at least eight

hours before using the UPS is recommended.

Energy loss may occur during shipping or

storage. To recharge the battery, simply plug

the UPS into an AC outlet.

Once the power

cord is connected, the UPS batteries will

automatically start charging.

2) Connect the loads

Plug your primary equipment into the battery

power-supplied outlets UPS 1 and UPS 2 .

Plug your peripheral equipment to the bypass

outlet. Do not plug high-current equipment

such as power amplifiers, projectors, and large

mixing consols into the UPS 1 or 2 outlets, as

they may cause the circuit breaker to trip. It is

recommended that heavy loads be connected

to the bypass outlet.
3) Connect the telephone

If you wish to protect a fax or modem, connect

the telephone cable from the wall outlet to

the “IN” jack. Connect the telephone cable

(provided) from the “OUT” jack to the fax

or modem. These ports are not for network

protection.

4) Connect to the utility power

Plug the UPS to a grounded AC receptacle.

Avoid using extension cords. If used, make

sure they are rated for at least 15 amps.
5) UPS self-test

The UPS will conduct a self-test each time it

is switched on. Do not add or remove any

equipment while the UPS conducts this self-

test; wait until the Power indicator lights up,

once completed, switch on your equipment.
6) Overload protection

If an overload situation (more than 5 amps

load) is detected during self-test, the UPS

audible alarm will activate, emitting a long

beep and then will automatically shut down

the system. If this occurs, unplug at least one

piece of equipment from the battery supplied

outlets. Switch off the UPS, wait 5 seconds

and check to make sure the circuit breaker is

set, then switch it on again.

7) Optimal battery status

To maintain the optimal status of the battery,

leave the UPS plugged in at all times.
8) Self-protection feature

The UPS is equipped with a self-protection

feature which prevents people from tampering

with the unit and subsequently damaging it. It

is programmed so that once it is switched off,

the user must wait 5 seconds before switching

it on again.
9) Storage

Cover and store the UPS with the battery fully

charged. During extended storage, recharge

the batteries every three months to ensure

battery life.

3

UPS1

Test

Switch

Off

On

Silence Buzzer

UPS2

Bypass

Remote

Port

Remote

Port

OUT

BREAKER

BREAKER

INPUT

INPUT

BYPASS

BYPASS

UPS2

UPS2

UPS1

UPS1

TEL/MODEM

IN

OUT

TEL/MODEM

IN

Battery Fault

AC Normal

Battery in use

SB-1000 E Rear Panel

1 2 3 4 5 6 7