Fireplace installation – FMI PFS DVF42NH-HA User Manual

Page 16

background image

www.fmiproducts.com

125078-01B

16

FirePLAce inStALLAtiOn

CHECK GAS TYPE

Use proper gas type for the fireplace unit you

are installing. If you have conflicting gas types,

do not install fireplace. See retailer where you

purchased the fireplace for proper fireplace

according to your gas type.

INSTALLING GAS pIpING TO

FIREpLACE LOCATION

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: For propane/LP

units, never connect fireplace di-

rectly to the propane/LP supply.

This heater requires an external

regulator (not supplied). Install

the external regulator between

the fireplace and propane/LP

supply.

WARNING: For natural

gas, never connect fireplace to

private (non-utility) gas wells.

This gas is commonly known

as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you

have the items listed below.

• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

• approved flexible gas line with gas connec-

tor (if allowed by local codes)

* An equipment shutoff valve with 1/8" NPT

tap is an acceptable alternative to test gauge

connection. Purchase the equipment shutoff

valve from your retailer.

For propane/LP connection only, the installer

must supply an external regulator. The exter-

nal regulator will reduce incoming gas pres-

sure. You must reduce incoming gas pressure

to between 11" and 14" of w.c. pressure. If

you do not reduce incoming gas pressure,

fireplace regulator damage could occur. Install

external regulator with the vent pointing down

as shown in Figure 18. Pointing the vent down

protects it from freezing rain or sleet.

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" diameter or greater to allow

proper gas volume to fireplace.

If pipe is too small, undue loss

of volume will occur.

Installation must include an equipment shutoff

valve, union and plugged 1/8" NPT tap. Locate

NPT tap within reach for test gauge hook up.

NPT tap must be upstream from fireplace (see

Figure 19, page 17).
IMPORTANT: Install main gas valve (equip-

ment shutoff valve) in an accessible location.

The main gas valve is for turning on or shutting

off the gas to the appliance.

Figure 18 - External Regulator with Vent

Pointing Down (Propane/LP Only)

Propane/LP

Supply Tank

External Regulator

with Vent Pointing

Down