beautypg.com

Condensing unit, Warning, Fig. 6 – Hoshizaki KMS-1400MLH User Manual

Page 19: Fig. 7

background image

1

2. Condensing Unit

1) Connect the wire harness wires to the appropriate terminals on the condensing unit's

terminal board using the wiring label or Fig. 8 as a reference. Be sure to connect the
ground wire (included in the wire harness).

2) Supply power from the electrical panel to the condensing unit. (This differs from KM

style installations.)

3) Connect the wire leads in the power supply junction box to the power supplied from the

disconnect or electrical panel. Connect a ground wire to the ground screw.

4) Replace all removed parts and panels in their correct positions.
5) Turn on the power supply to the condensing unit.

WARNING

1. Be sure the ground circuit for both units has been properly installed.
2. The condensing unit should have power for a minimum of 4 hours prior to

startup to prevent compressor damage.

Fig. 6

WARNING

ELECTRICAL CONNECTION

The white lead must be connected
to the neutral conductor of the power
source.
Miswiring results in severe damage to
the icemaker.
(See Fig. below.)

0-0/0/1
( wire with neutral for 11V)

Power Supply
Junction Box

Brown

White

Black

L1

N

L

0

-

0V

11

-

1

0V

Fig. 7