beautypg.com

Cartridge performance data sheet, Cartridge performance, Data sheet – Hotpoint 22 User Manual

Page 27: Performance data sheet

background image

27

Performance Data Sheet

Hotpoint SmartWater Filtration System

HWF Cartridge

Health Claim Performance Certified by NSF/ANSI*
(100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

Parameter

USEPA

Influent

Effluent

% Reduction

MCL

Challenge

Average

Maximum

Average

Minimum

Chlorine

1.9 ppm

0.02 ppm

0.05 ppm

98.90%

97.37%

T & O

Particulate**

200,000

3,978

7,800

98.00%

96.10%

Standard No. 53: Health Effects

Parameter

USEPA

Influent

Effluent

% Reduction

MCL

Challenge

Average

Maximum

Average

Minimum

Turbidity

1 NTU***

24.3 NTU

0.07 NTU

0.1 NTU

99.71%

99.59%

Cysts

99.95% Reduction

105,750

26

55

99.97%

99.95%

Lead at pH 6.5

15 ppb

160 ppb

1 ppb

1 ppb

99.37%

99.37%

Lead at pH 8.5

15 ppb

150 ppb

1.8 ppb

4.3 ppb

98.80%

97.13%

Lindane

0.0002 ppm

0.00062 ppm

0.00005 ppm

0.00005 ppm

91.93%

91.93%

Atrazine

0.003 ppm

0.0084 ppm

0.002 ppm

0.003 ppm

76.19%

64.28%

2,4-D

0.100 ppm

0.272 ppm

0.042 ppm

0.090 ppm

84.89%

67.63%

Asbestos

99%

690 MFL/ml

0.32 MFL/ml

1.2 MFL/ml

99.95%

99.82%

* Tested using a flow rate of 0.5 gpm; pressure of 120 psig; pH of 7.5±0.5; temp. of 20±2.5 C
** Measurement in particles/ml
*** NTU = Nephelometric Units

Operating Specifications

Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light;

up to one year for models with a replacement filter indicator light

Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock

Temperature: 33-100 F (0.6-38 C)

Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 3 minutes to purge out trapped air.

Replace cartridge when flow becomes too slow.

Special Notices

Installation instructions; parts and service availability; and standard warranty are included with the product when shipped.

This drinking water system must be maintained according to manufacturer’s instructions, including replacement of

filter cartridges.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after

the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.

Check for compliance with the state and local laws and regulations.

Manufactured for: General Electric Company, Louisville, KY 40225

NSF

®

System Tested and Certified by NSF International against ANSI/NSF

Standard 42 & 53 for the reduction of:

Standard No. 42: Aesthetic Effects

Chemical Unit

Taste and Odor Reduction

Chlorine Reduction, Class I

Mechanical Filtration Unit

Particulate Reduction, Class I

Standard No. 53: Health Effects

Chemical Reduction Unit

Lead and Atrazine Reduction

Lindane and 2,4-D Reduction

Mechanical Filtration Unit

Turbidity Reduction

Cyst and Asbestos Reduction

This manual is related to the following products: