Stove specifications, Gas stove specifications, Clearances to combustibles – Hearth and Home Technologies TIARA II User Manual
Page 4

Stove Specifications
Dimensions above are in inches; technical drawings are in inches and millimeters. Reference dimensions only. We recommend measuring individual units at installation.
Refer to installation manual for detailed specifications on installing this product. Heat & Glo reserves the right to update units periodically. The flame and ember appearance may
vary based on the type of fuel burned and the venting configuration used. Actual product appearance, including flame, may differ from product images..
Gas Stove Specifications
MODEL
HEIGHT
FRONT WIDTH
BACK WIDTH
DEPTH
GLASS SIZE
Paloma-no surround
40-3/4
18-7/8
18-7/8
15-7/8
18-1/2 x 34-1/2
Paloma-with surround
44-1/4
24-3/4
24-3/4
16-7/8
18-1/2 x 34-1/2
Tiara Petite
22-3/4
18-1/8
18-1/8
17-3/8
13 x 10-1/2
Tiara I
27
35-1/2
35-1/2
20-1/4
14 x 13-1/4
Tiara II
29-1/4
41-3/4
41-3/4
22-1/4
22-1/2 x 14-1/4
20802 Kensington Boulevard, Lakeville, MN 55044
(888) 427-3973 (952) 985-6000
Web: heatnglo.com
A brand of Hearth & Home Technologies Inc.
For complete information and valuable assistance on
these models, please contact us at:
Clearances to Combustibles
18-7/8
[478]
15-7/8
[404]
7-1/8
[181]
28-7/8
[733]
30
[762]
34-1/2
[877]
18-1/2
[470]
40-3/4
[1035]
34-5/8
[879]
34-1/8
[867]
Paloma with optional hearth pad
Top
Front
Side
24-3/4
[629]
30-1/4
[768]
2-1/4
[83]
16-7/8
[429]
29-5/8
[753]
34-1/2
[877]
18-1/2
[470]
44-1/4
[1126]
34-5/8
[879]
Top
Front
Side
Rear
Rear
Paloma with Surround with optional hearth pad
35-1/2 [902]
23-1/4 [590]
9-3/8
[237]
27
[686]
20-1/4
[514]
Tiara I
Front
Top
Side
41-3/4 [1060]
29-1/2 [749]
9-1/2
[240m]
29-1/4
[743]
22-1/4
[565]
Tiara II
Front
Top
Side
27-3/8 [695]
15-3/8 [384]
17-3/8 [441]
22-3/4
[578]
16-1/4
[413]
18-1/8 [460]
Tiara Petite
Front
Side
Rear
Alcove
E
F
B
I
G
D
C
H
A
J
A
C
“A” measurement is from
appliance top, not side.
A
K
K
Model
A
B
C
D
E
F
G
H
I
J
K
Paloma
6
10-1/8 12-1/8
54
36 30-3/4 13-1/4 13-1/4
1
15-1/2
5
Model
A
B
C
D
E
F
G
H
Top of pipe
Side of pipe
Inside outside
corner wall vent
Tiara I
8-1/2 1/4
3/8
54
36
40
27
1-1/2
1
9
Tiara II
5-1/4 1/4
3/8
54
36
40
31-3/4
1-1/2
1
9
Model
A
B
C
D
E
F
G
H
Tiara Petite
6
2
2
43
36
30
20-1/4
19-1/2
A
B
F
E
A
"A" measurement is from
stove top, not side
C
C
A
G -Alcove
A
D
H
Clearances are in inches. See installation manual for more information
* Vertical measurement includes optional hearth pad height of 3/8"
*
*
*
*
*
Model
Btu/Hour Input
(NG)
Steady State
Efficiency
AFUE
Efficiency
Paloma - no surround
22,500 - 30,000
73%
71.5%
Paloma - with surround
22,500 - 30,000
73%
71.5%
Tiara Petite
12,000 - 17,000
83%
68%
Tiara I
22,000 - 31,000
83%
68%
Tiara II
27,000 - 38,500
83%
68%
HNG-1054U-0308