Honeywell S9371A User Manual
Application, Specifications
INSTALLATION INSTRUCTIONS
69-2076-01
S9360A, S9361A, S9370A, S9371A
Integrated Boiler Controllers
APPLICATION
These integrated boiler control modules provide ignition
sequence, flame monitoring and safety shutoff for either
intermittent pilot spark ignition or direct hot surface
ignition heating systems. They also provide limit rated
water temperature control and display interface capability
for either “on-board” or remote user interface
applications.
• S9360A—Spark Ignition, Intermittent Pilot, Remote
Display.
• S9361A—Spark Ignition, Intermittent Pilot, “On board”
Display.
• S9370A—Hot Surface Ignition, Remote Display.
• S9371A—Hot Surface Ignition, “On board” Display.
• Enabled with EnviraCOM™ communication capability
to support remote monitoring and diagnostics.
• Limit-rated Temperature Sensing Probe.
• One or Two Sensor Models.
SPECIFICATIONS
IMPORTANT:
The specifications given in this publication do
not include normal manufacturing tolerances.
Therefore, an individual unit may not match the
listed specifications exactly. Also, this product is
tested and calibrated under closely controlled
conditions, and some minor differences in
performance can be expected if those
conditions are changed.
Model Numbers
Dimensions:
See Fig. 1.
S—Switching Control
9
3—Integrated Hydronic Control Platform
6—Spark Ignition
7—Hot Surface Ignition
0—Remote Display Required
1—Integrated On-Board Display
A—Boiler Control
B—Water Heater Control
C—Pool Heater Control
1—No Circulator
2—On/Off Circulator
S 9
3
6
0
A 1
000