Henny Penny BCC/BCR-140 User Manual
Page 9

Henny Penny
Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350
201
2-3
2-3. ELECTRICAL
Refer to the table below for electrical ratings for both models.
(Continued)
Model No.
Volts
Watts
Amps
Freq. Phase
BCC-140
200
4700
18
50/60
3
208-240
4700
18
60
3
230
4700
20
50
1
BCC-175
200
5800
20
50/60
3
208-240
5800
20
60
3
400
5800
9
50
3N
BCR-140
208-240
2400
12
60
1
230
2400
10
50
1
200
2400
12
50-60
1
BCR-175
200
2400
12
50/60
1
208-240
2400
12
60
1
230
2400
12
50
1
BFR &
200
4100
15
50/60
3
BCR-350
208-240
4100
15
60
3
400
4100
10
50
3N
2-4. LOCATION
The Blast Chillers should be placed in an area where the doors can
be opened, for loading and unloading, without interruption. For
proper operation, the cabinet must be level.
For maximum efficiency, if the air temperature of the premises
is more than 100° F (38° C), the room should have adequate
ventilation, taking into account for the heat emitted by the unit.
Clearances should be as follows:
BCC/BCR-140 Top ........... 16 in. (400 mm) for air circulation
Left Side ... 4 in. (100 mm) for air circulation
Right Side . 8 in. (200 mm) for air circulation
Back ......... 4 in (100 mm) for air circulation
Front ........ 26 3/8 in (668 mm) for door swing
BCC/BCR-175 Top ........... 16 in. (400 mm) for air circulation
Sides ........ 3 in. (70 mm) for air circulation
Front ........ 33 3/8 in. (847 mm) for door swing
BFR &
Top ........... 16 in. (400 mm) for air circulation
BCR-350
Sides ........ 3 in. (70 mm) for air circulation
Pass Thru
- Front and Back ... 38 1/8 in (970 mm) for door swing
Solid Back
-Front ................... 38 1/8 in. (970 mm) for door swing
Back ................... 4 in. (100 mm) for air circulation