PC auto setting
Sets the operational mode of the automatic position
adjustment in the [Position] menu.
[Off]:
Automatic position adjustment starts when SETUP> is pressed on the remote control or automatic position adjustment is executed from the [Position] menu. [On]: Other than remote control or menu operation, automatic position adjustment starts: • When the display power is turned ON. • When the input signal is switched. Off-timer function Enables / disables Off timer function. [Enable]: Enables the [Off-timer function]. [Disable]: Disables the [Off-timer function]. Note ● When [Disable] is set, the Off-timer is cancelled. Initial startup Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again. [Last memory]: Power returns in as the same state as before the power interruption. [On]: Power returns in power On. [Standby]: Power returns in standby mode. Note ● When using multiple displays, [Standby] is preferred to be set in order to reduce a power load. Display ID Sets ID number when controlling the Display with [Controller ID function] and [Serial ID function]. 0 ‒ 100 (Standard value: 0) Controller ID function Enables/Disables the ID remote control function. controller sold separately. (see page 115) [Off]: Disables the ID remote control function. (Can be operated as normal remote control.) [On]: Enables the ID remote control function. Note ● To use the ID remote control function, setting ID numbers both for the remote control and for the display unit is required. and display unit, see page 115 and [Display ID] respectively. ● About how to reset the settings to defaults: “Initialization” (see page 77) Serial ID function Set to control external control with the PC connected to SERIAL terminal according to the Display’s ID number (Panel ID). [Off]: Disables external control by the ID. [On]: Enables the external control by the ID. Serial response(Normal) Sets whether to send the response command to normal commands without ID. [Off]: Does not respond. (Including the inquiry command) [On]: Responds. Serial response(ID all) Sets whether to respond to the command or not, when serial command of ID No “0” is received. [Off]: Does not respond. [On]: Responds.
(Power Indicator: green)
(Power Indicator: red/orange)
To operate this function, please purchase ID remote
Effective on switching to [On].
For ID number setting for the remote control