beautypg.com

Wiegand and other cable connections, Restoring the factory defaults, Resetting the baud rate of rs-485 – Suprema XPass D2 Outdoor Compact RFID Reader User Manual

Page 11: Installation

background image

Installation

11

Wiegand and other cable connections

Restoring the Factory Defaults

This will reset all settings stored on the device.

1

Turn the power on.

2

Press the reset button three times quickly.

3

When the yellow LED is blinking, press the reset button again.

Resetting the baud rate of RS-485

1

Turn the power on.

2

Press and hold the reset button for more than 2 seconds. When the device change to setup mode, the yellow LED is blinking.

3

Depending on the number of times the reset button was pressed, the baud rate changes. You can recognize the baud rate

according to the LED color.

The number of times

Baud Rate

LED Color

1

9600

Cyan

2

19200

Blue

3

38400

Magenta

4

57600

White

5

115200

Red

4

The LED blinks for 5 seconds with the color set as the above. The baud rate is set once you hear a beep sound.

NOTE

If you do not press the reset button after changing to the setup mode, the baud rate is set to 115200.


1 - PWR +VDC

Red

2 - GND

Black (White stripe)

5 - WG D0

Green

6 - WG D1

White

7 - LED RED

Orange

8 - LED GRN

Brown

9 - BEEP

Purple

10 - TMPR

Gray

Control device

XPass D2

DC power