页 12, C.fn: setting custom functions, Protection function – Godox VING V860IIS TTL Li-Ion Flash Kit for Cameras User Manual

Page 13: Over-temperature protection, Other protections

background image

C.Fn: Setting Custom Functions

The following table lists the available and unavailable custom

functions of this flash.

m/ft

APO

AF

Sv APOT

BEEP

LIGHT

LCD

m

ft

ON

OFF

ON

OFF

60min

30min

ON

OFF

12sec

OFF

ON

0~9

Distance indicator

Auto power off

AF-assist beam

Slave auto power

off timer

Beeper

Backlighting time

LCD contrast ratio

- 49 -

- 50 -

C

.

Fn

Custom

Functions

Custom Function
Signs

Function

Setting No

.

Settings & Description

m

feet

ON

OFF

ON

OFF

60min

30min

ON

OFF

Off in 12 sec.

Always off

Always lighting

10 levels

1

.

Press

<

Zm

/

C

.

Fn

>

Backlight

/

Custom

Setting Button

for

2

seconds

or

longer

until

C

.

Fn

menu

is

displayed

.

The

Ver

x

.

x”

in

the

top

-

right

corner

refers

to

the

software

version

.

2

.

Select

the

Custom

Function

No

.

Turn the Select Dial to

select

the

Custom

Function

No

.

3

.

Change

the

Setting

.

Press

<

SET

>

button

and

the

Setting

No

.

blinks

.

Turn

the

Select

Dial

to

set

the

desired

number

.

Pressing

<

SET

>

button

will

confirm

the

settings

.

After you set the Custom Function and press Function Button 4

< > to exit, then the camera will be ready to shoot.

4. In the C.Fn states, long press the “Clear” button for 2 seconds

until “OK”is displayed on the panel, which means the values in

C.Fn can be reset.

Protection Function

1. Over-Temperature Protection

To avoid overheating and deteriorating the flash head, do not fire

more than 30 continuous flashes in fast succession at 1/1 full

power. After 30 continuous flashes, allow a rest time of at least 10

minutes.

If you fire more than 30 continuous flashes and then fire more

flashes in short intervals, the inner over-temperature protection

function may be activated and make the recycling time over 10

seconds. If this occurs, allow a rest time of about 10 minutes, and

the flash unit will then return to normal.

When the over-temperature protection is started, is shown on

the LCD display.

Number of flashes that will activate over-temperature protection:

Meaning

A failure occurs on the recycling system so that the

flash cannot fire.

Please restart the flash unit. If the problem still exists,

please send this product to a maintenance center.

The system gets excessive heat. Please allow a rest

time of 10 minutes.

The voltage on two outlets of the flash tube is too high.

Please send this product to a maintenance center.

There are some errors occurred during the upgrading

process. Please using the correct firmware upgrade

method.

Prompts on LCD Panel

E1

E2

E3

E9

2. Other Protections

The system provides real-time protection to secure the device and

your safety. The following lists prompts for your reference:

Number of flashes that will activate over-temperature protection in

high-speed sync triggering mode:

Power Output Level

1/1

1/2 +0.7

1/2 +0.3

1/2

1/4(+0.3,+0.7)

1/8(+0.3,+0.7)

1/16(+0.3,+0.7)

1/32(+0.3,+0.7)

1/64(+0.3,+0.7)

1/128(+0.3,+0.7)

Number of Flashes

30

40

50

60

100

200

300

500

1000

Power Output

1/1

1/2(+0.3,+0.7);

1/4(+0.3,+0.7)

1/8(+0.3,+0.7);

1/16(+0.3,+0.7)

1/32(+0.3,+0.7);

1/64(+0.3,+0.7);

1/128(+0.3,+0.7);

Times

15

20

30

40

50