3. After 30 minutes, remove the reflector or softbox from the Bowens mount.
4. Use needle-nose pliers to carefully unhook the
retention spring wrapped around the top of the
flashtube. Make sure it’s disengaged from the flash
tube.
5. Once it’s unhooked, wear a pair of white cotton
gloves or hold a soft, dry cloth to grip the base of
the flashtube on each side, and carefully pull the
flashtube from the flash unit.
6. Push the pins of the new flashtube into the sockets,
using firm and even pressure at its base.
7. Use needle-nose pliers to fasten the retention
spring over the hook above the flashtube.
8. After the flashtube has been secured, replace the reflector or softbox.
4