(3) Data Format
Stable transmission (
) / Continuous transmission (
)
Press the
↵ key to transmit ( )
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18
kg/lb
HEAD
1
,
HEAD
2
,
DATA
UNIT
CR LF
HEAD 1 ( 2 BYTES )
HEAD 2 ( 2 BYTES )
OL - Overload , Under load TR - TARE Mode
ST - Display is Stable
NT - NET Mode
US - Display is Unstable
GS - GROSS Mode
DATA (8 or 9 BYTES)
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT ( 2, 3 or 4 BYTES )
kg
= 6B ( HEX )
;
67 ( HEX )
lb = 6C ( HEX )
;
62 ( HEX )
tl.T
= 74 ( HEX )
;
6C ( HEX )
;
2E ( HEX )
;
54 ( HEX )
hkg
= 68 ( HEX )
;
6B ( HEX )
;
67 ( HEX )
Transmission example:
1. The gross weight (+0.876kg) shows as below, after stable: (in the tare mode)
S T
,
G S
,
+
0
.
8
7
6
k
G 0D 0A
HEAD 1 , HEAD 2 , DATA UNIT
CR LF
2. The net weight (-1.568lb) shows as below without weight stability: (Not in the tare mode)
U S
,
N T
,
-
1
.
5
6
8
l
b 0D 0A
HEAD 1
, HEAD 2, DATA UNIT
CR LF
3. The net weight (+0.876kg) shows as below, after stable: (in the tare mode)
S T ,
T R ,
+
0
.
8 7 6 k G 0D 0A
HEAD , HEAD ,
DATA UNIT
C
LF