beautypg.com

Trouble shooting, Gb mt – Parkside PSBS 240 B2 User Manual

Page 63

background image

63

GB MT

Trouble Shooting

Always disconnect the plug from the mains socket before working.

Danger of electric shock.

Problem

Possible Cause

Error correction

Device doesn‘t start

Mains voltage missing

Main circuit breaker is tripped

Check the socket, mains cable,

line, mains plug, repairs to be

carried out by qualified electri-

cian if necessary, check main

circuit breaker.

On/off switch (

14) may be

defective

Repair by Customer Care

Engine faulty

Grinding tools do

not move although

the engine is run-

ning

Grinding disc nut (

19a)

loose

Tighten grinding disc nut (see

„Changing the grinding disc“)

Grinding belt (

10) loose

Increase grinding belt tension

(see „Changing the grinding

belt“)

Drive is blocked

Grinding belt (

10) block-

ing drive

Re-mount grinding belt (see

„Changing the grinding belt“)

Workpiece, remaining work-

pieces or remaining grinding

tools block drive

Remove blockages

Engine is slower

and stops

Device is overloaded through

workpiece

Reduce pressure on grinding tool

Workpiece unsuitable

Grinding disc does

not rotate smoothly,

abnormal noises

can be heard

Grinding disc nut (

19a)

loose

Tighten grinding disc nut (see

„Changing the grinding disc“)

Grinding disc (

19) faulty

Change grinding disc

Spark protection (1) or work-

piece support (

6/18) set

incorrectly

Set spark protection or work-

piece support (see „Assembly“)

Bad grinding out-

put

Grinding belt (

10) worn

Change grinding belt