Dealing with unsatisfactory printing – iSys iTerra TL1290 Color LED Printer User Manual
Page 30

 
 
28
Your print media is creased or curled.
Use appropriate media. Decurled media can be used.
Your print media sheets are not aligned with 
each other. 
Remove the sheets, jog them into alignment and reload them.
Y our print media is not aligned properly in the 
paper tray. 
Adjust the paper stop and paper guides of the tray, or the 
manual feed guide on the MP Tray to align the media properly. 
Dealing with Unsatisfactory Printing
SYMPTOMS
POSSIBLE CAUSES
STEPS TO TAKE
Vertical white lines 
can be seen on the 
printed page. 
The LED head is dirty.
Wipe the LED head with a LED lens cleaner or with a soft 
cloth.
The toner is low.
Replace the toner cartridge.
Foreign materials may be 
present in the image drum.
Replace the image drum cartridge.
Light-shielding film of the 
image drum cartridge is dirty. 
Wipe the film with a LED lens cleaner or with a soft cloth.
Printed images are 
fading vertically. 
The LED head is dirty.
Wipe the LED head with a LED lens cleaner or with a soft 
cloth.
The toner is low.
Replace the toner cartridge.
The paper is not suitable for 
the printer. 
Use recommended paper.
Printing is light.
The toner cartridge is not 
properly seated 
Reinstall the toner cartridge.
The toner is low.
Replace the toner cartridge.
The paper is moist.
Use paper stored in proper temperature and humidity 
conditions 
The paper is not suitable for 
the printer. 
Use recommended paper.
Thickness and type of paper 
are inappropriate. 
Set a proper value for [Media Weight] and [Media Type] in 
the menu setup, or set one value thicker for [Media Weight]. 
Partially faded 
images. White 
spots and lines 
appear in solid 
printing. 
Paper is moist or dry
Use paper stored in proper temperature and humidity 
conditions 
Vertical lines 
appear. 
The image drum cartridge is 
damaged. 
Replace the image drum cartridge.
The toner is low.
Replace the toner cartridge.
Horizontal Lines 
and spots appear 
periodically. 
When the interval is about 
94mm (4in), the image drum 
(the green tube) is damaged 
or dirty. 
Wipe it lightly with a soft cloth. Replace the image drum 
cartridge when it is damaged. 
When the interval is about 
42mm (1.5in), there may be 
foreign particles in the image 
drum cartridge. 
Open/close the top cover, and print again.
When the interval is about 
87mm (3.5in), the fuser unit 
is damaged. 
Replace the fuser unit.
The image drum cartridge 
has been exposed to light. 
Replace the image drum cartridge if the problem is not 
resolved. 
White area of paper 
is lightly stained. 
Paper contains static.
Use paper stored in proper temperature and humidity 
conditions. 
The toner is low.
Replace the toner cartridge.
Periphery of the 
letters is smudged. 
The LED head is dirty.
Wipe the LED head with a LED lens cleaner or with a soft 
cloth.
Toner comes off 
when it is rubbed. 
The thickness and type of 
the paper are incorrectly set. 
Set the correct value of [Media Type] and [Media Weight] in 
the menu setup or set one value thicker for [Media Weight]. 
Glossiness is not 
uniform. 
The thickness and type of 
the paper are incorrectly set. 
Set the correct value of [Media Type] and [Media Weight] in 
the menu setup or set one value thicker for [Media Weight]. 
 
 