beautypg.com

Lowel prime location, Led control panel – Tiffen Lowel Prime Location LED (Daylight & Tungsten Models) User Manual

Page 2

background image

Lowel Prime Location

LED Control Panel

AC / DC Power Switch

The Location Prime LED can be powered
by AC, or DC with attached V-lock or Anton
Bauer type battery. Press the Power Switch to
the left side, for AC, or the right side for DC.
In the switch's middle setting, the fixture is
powered off.

AC Power In & Out

From the wall outlet, the Prime Location
LED AC cable plugs into the top Powercon
Connector, shown above, with a twist-lock
action. Be sure the cable is securely locked.
The fixture will auto-set itself from 90-240
VAC. (Use the proper cable for the country
of use.) The AC Bridged Output allows
jumper PowerCon cables to pass AC power
from fixture to fixture in a chain of Location
Prime LED's. This can be helpful when
access to individual AC outlets is limited.

Note –

When using the AC bridge PowerCon

connection, pay attention to the total amper-
age consumption of the chain on the AC cir-
cuit. Do not overload.

Prime Location LED Operation

Operation

Turning on the Power in either AC or DC
operation switch causes the fixture to light at
whatever dimming level it was at when last
powered down (factory shipped at 100%).
The unit will retain its previous dimming level
even if unplugged.

Dimming to 100%

Lowel Prime Location fixtures can be dimmed
manually on the rear of the unit, without visi-
ble color shift. To dim the light to a desired
level, press the Up & Down buttons to set
dimming level from 1-100.

Fuse

Always power down & unplug the fixture
before changing its fuse. Open the fuse hold-
er with a phillips head screwdriver to replace
the fuse. Lowel Prime Location LED's use
fuses rated at 3 Amps and 250 Volts.

Barndoor Softening Set

Due to the 'multi point-source' nature
of most LED fixtures, it is common to have
an undesired multi-shadow effect, when
using barndoors to trim the beam. This set
includes a 4 way barndoor, subtle diffusion
gel, and Gel-jawz clips, to minimize multi-
shadow, while still allowing a
visible barndoor cut.

Includes:

4 way

adjustable
Barndoor, Prime Lite
Diffusion Gel, Lowel
Gel-jawz (4)

Code: PL-120

Lowel Prime Location™ Light Control Accessories mount on the front of the fixture
using the 2 slots. The rear slot, closest to the LEDs, should be used for the gel
frame, with the front slot used for either of the below listed accessories. Make sure
top corner fixture Accessory Lock is engaged to secure accessories.

Prime Location Accessories

Honeycomb Grid

Honeycomb grids control the spill of the
light, by attaching to the front of the fixture.
The grid is available in 20 degree dispersion.

20° Honeycomb

Output Loss - aprox 54%

Code: PL-132

Repairs, problems, suggestions
and requests for brochures/catalogs,
instructions and parts lists can be
handled through your Authorized Lowel
Dealer/Distributor or directly through
Lowel. Electrical repairs should

be made only by Lowel or by
a qualified electrician.
Lowel Prime Location LED equipment is a prod-
uct of the ongoing collaborative relationship
between Lowel-Light and Fluo-Tec, Mexico

Problems, repairs & info

LED Display

AC/DC Power Switch (Center Off)

Dimming Buttons: Down/Up

Battery Plate Connection

AC Input

AC Bridged Output

Fuse

90 Oser Avenue, Hauppauge, N.Y. 11788
Call: 800 645-2522 or 631-273-2500
Fax: 631-273-2557

e-mail:

[email protected]

www.lowel.com

Lowel-Light Manufacturing, Inc.

Uni Sr. Stand

Code: UN-66
Weight:

3.3 lbs (1.5 kg)

Size:

22.5" (57.2 cm) folded.

Maximum height:

7' (2.2 m)

Suggested Stands

KS Jr. Stand

Code: DT-33
Maximum height:

7'7" (2.3 m),

Collapsed length:

2'4" (65 cm)

Weight:

3.5 lbs (1.6 kg)

Safety Cable (3)

Code: CM-50

Weight: 2 oz (57 g)

Battery Use

Battery run-time will vary
with battery model, age and
charging level. Both Location
Prime battery plates are user
removable & swappable, via
a multi pin connector
beneath the plate.

For use in rain or
dust/sand, make sure
battery is also rated
for IP-65 use.

V-Lock Mount

Code: PLPLVLMNT

Anton Bauer
Gold Mount

Code: PLABMNT

ver. 1.0 © Lowel-Light Mfg., Inc 2014 926

AC Use

Lowel Prime Location LEDs use Powercon connector AC cables. The fixture will auto-set itself
to international voltages. See the listed cables if adapting for use in another country.
For IP-65 use, do not use switched AC cables.

Also, Prime Location LEDs can be ganged together using AC Bridging cables when AC outlets
are scarce. With each fixture drawing aprox 1 amp, a 20 amp circuit could accommodate
15+ fixtures. Do not overload AC circuits.