beautypg.com

Tiffen Lowel Prime Location LED (Daylight & Tungsten Models) User Manual

Prime location led instructions

background image

Lowel Prime Location™ LED
equipment is a professional
lighting system. Read these
instructions, as well as acces-
sory instructions and applicable
warnings before operating.

n

Do not leave fixture

unattended. For fixed

(stationary) use in studio's,
theaters, and similar locations.

n

Not for household use.

Use only for photographic lighting

(video & film imaging).

n

Always unplug unit before

changing fuse.

n

Never bypass plug’s

ground pin.

n

Do not interfere with

unit’s ventilation.

n

Do not operate unit with

Accessory Barndoors closed.

n

Make sure clamp is tightened

at yoke.

n

Always use with supplied

Lowel AC Cable.

n

Always use Safety Cable,

when attaching to overhead

pipes or grids.

n

Make sure Accessory Lock is

engaged to to secure accessories.

Warnings

LED Warnings

n

Avoid looking directly

at the LED's for extended periods
of time.

n

LED's take time to reach

standard operating output level,
and frequently have slightly
higher output during the first
1/2 hr, when powered up.

IP-65 Rating

(IP= Ingress Protection)

n

Prime Location LED is

protected

against all dust,

sand and dirt, as well as rain.

On Stand:

The recommended Lowel Stand
for the light is the Uni-66 stand
(UN-66) or larger. Set the stand
risers at less than full extension,
for most stable operation, and if
tilting the light down, make sure
1 leg of the stand is extended
straight out in front of the light
for best balance.

Prime Locations' yoke is placed off
center vertically in the unit. This is
to allow a more full tilting range.

Make sure to tighten the side
locking knob fully to prevent
slippage.

Mounting the Fixture

Fuses & Power Consumption

Female 5/8"
Stand-fitting:

For use on stand only. Allows
mounting the fixture on 5/8" male
stand stud. Stand fitting comes with
a locking washer and a flat washer.
Mount with the locking washer
above the flat washer on the top
side of the yoke, under the bolt
head. Attach the female stand-fitting
tightly and rotate yoke so it is now
on the underside of the fixture.
Tighten yoke, clamp locking lever,
and place female stand-fitting over
stand, making sure that its locking
screw is loosened enough to allow
the fitting to completely fit over the
5/8" stand stud. Tighten knob, mak-
ing sure its screw is under the safe-
ty cut of the stand fitting stud. Add
additional weight to base of stand
for increased stability.

On Lighting Rail:

Due to the shortened yoke on Prime
Location LED, when hanging the
fixture from rail or pipe, fixture
should be positioned upside down
(see photo). If using with gel frame
or any other front light controls
installed, be sure that top corner
accessory guide lock on the fixture
is fully engaged. Attach clamp
tightly to yoke of fixture, according
to clamp mfrs. instructions. Hang
clamp on pipe or grid and tighten
the large screw so that the clamp
and fixture are securely mounted.

Attach safety cable between the
fixture and the rail for necessary
security.

Supplied with:

Gel Frame, selected Battery Plate,
Safety Cable, 5/8" Female Stand
Fitting and 10' unswitched AC
Cable (PC1-808 ). Other AC cable
connection options are available.

Weight:

10.5 lbs (4.76 kg)

Code: PL-01VTU

Tungsten color,

V-lock plate

Code: PL-01ATU

Tungsten color,

Gold Mt plate

Code: PL-01VDA

Daylight color,

V-lock plate

Code: PL-01ADA

Daylight color,

Gold Mt plate

Specs & Performance: Daylight & Tungsten Models

Performance

Lowel C-Clamp
(FLS-803)

Female 5/8"
Stand Fitting

Safety
Cable

Note –

Most electrical equipment briefly consumes a higher amount of

electrical current during startup (ignition). Consult the below chart to con-
firm that your electrical wiring is sufficient for the fixtures used. All fuses
must be rated at 250VAC.

Lowel Prime Location LED's auto-set from 90-240 VAC.
Fixture consumes 82 Watts and has a Power Factor of .97

Using Prime Location LED in Rain
or Dust/Sand Storms

Prime Location LED's IP-65 rating means the fixture is sealed
against dust & sand, and protected from water splashing on it from
any direction, such as a rainstorm.

110V 240V

Model Fuse Nominal Peak Nominal Peak

Current Ignition Current Ignition
Current Current

ALL 3 A / 250 V 0.714 A 0.97 A 0.403 A 0.61 A

AC Use

When using the fixture with AC
power, in rain or dust environ-
ments, it will be protected at the
fixtures locking Powercon connec-
tor. Also ensure that the AC outlet
the fixture is plugged into is pro-
tected. When not in
use, make sure AC
connections have
their rubber covers
securely in place.

DC Use

Prime Location's V-Lock or
Gold Mount battery plates are also
sealed against rain & dust when
not in use.

For IP-65 protection you must
also use batteries that are rated
for IP-65 use.

Before attaching in damp
environments, make sure the
battery pins are wiped dry.

Beam Angles:

Points at which intensity drops to 50% of maximum.

Foot Candle readings taken at center of beam, using a Minolta CL-200 meter.

Daylight Model

Tungsten Model

Each fixture has installed LEDs totalling 5800-6000 lumens

Prime Location LED Instructions

(Daylight & Tungsten Models)


16" (40.6 cm)

12

.2

5"

(

31

c

m

)

16

.2

5"

(

41

.3

c

m

)


4.75" (12 cm)


Accessory Lock

This manual is related to the following products: