beautypg.com

9 dds0 register – 0x8 – control function register, Dds0 register – 0x8 – control function register – Sundance SMT399-160 User Manual

Page 23

background image

Setting

Internal

Profile

Control

(Bit 13-11)

Description

Internal

Profile

control.

DDS0 Register – 0x7 – Control Function Register

Setting

Load ARR

@IO UD

(Bit 10)

Description

0

0

The Amplitude Ramp Rate timer is loaded only upon timeout and is not loaded due to an Io
Update input signal.

1

1

The Amplitude Ramp Rate timer is loaded only upon timeout and is loaded due to an Io Update
input signal.

DDS0 Register – 0x7 – Control Function Register

Setting

OSK

Enable

(Bit 9)

Description

0

0

Shaped on-off keying is bypassed.

1

1

Shaped on-off keying is enabled.

DDS0 Register – 0x7 – Control Function Register

Setting

Auto OSK

Keying

(Bit 8)

Description

0

0

Manual on-off keying operation selected.

1

1

Automatic on-off keying operation selected.

DDS0 Register – 0x7 – Control Function Register

Setting

Auto Synch

Enable

(Bit 7)

Description

0

0

The auto synchronisation of multiple AD9954 is inactive.

1

1

The auto synchronisation of multiple AD9954 is active.

DDS0 Register – 0x7 – Control Function Register

Setting

Soft

Manual

Synch (Bit

6)

Description

0

0

The manual synchronisation of multiple AD9954 is inactive.

1

1

The manual synchronisation of multiple AD9954 is active.

DDS0 Register – 0x7– Control Function Register

Setting

Linear

Sweep

Enable

(Bit 5)

Description

0

0

The linear frequency sweep capabilities are inactive.

1

1

The linear frequency sweep capabilities are active.


5.4.9 DDS0 Register – 0x8 – Control Function Register.
For more details, refer to AD9954 datasheet.

DDS0 Register – 0x8 – Control Function Register

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

RefClk Multiplier

VCO Range

Charge Pump Current

Default

‘00000’ ‘0’

‘00’

User Manual SMT399-160

Page 23 of 39

Last Edited: 24/05/2007 17:12:00