9 dds0 register – 0x8 – control function register, Dds0 register – 0x8 – control function register – Sundance SMT399-160 User Manual
Page 23
Setting
Internal
Profile
Control
(Bit 13-11)
Description
Internal
Profile
control.
DDS0 Register – 0x7 – Control Function Register
Setting
Load ARR
@IO UD
(Bit 10)
Description
0
0
The Amplitude Ramp Rate timer is loaded only upon timeout and is not loaded due to an Io
Update input signal.
1
1
The Amplitude Ramp Rate timer is loaded only upon timeout and is loaded due to an Io Update
input signal.
DDS0 Register – 0x7 – Control Function Register
Setting
OSK
Enable
(Bit 9)
Description
0
0
Shaped on-off keying is bypassed.
1
1
Shaped on-off keying is enabled.
DDS0 Register – 0x7 – Control Function Register
Setting
Auto OSK
Keying
(Bit 8)
Description
0
0
Manual on-off keying operation selected.
1
1
Automatic on-off keying operation selected.
DDS0 Register – 0x7 – Control Function Register
Setting
Auto Synch
Enable
(Bit 7)
Description
0
0
The auto synchronisation of multiple AD9954 is inactive.
1
1
The auto synchronisation of multiple AD9954 is active.
DDS0 Register – 0x7 – Control Function Register
Setting
Soft
Manual
Synch (Bit
6)
Description
0
0
The manual synchronisation of multiple AD9954 is inactive.
1
1
The manual synchronisation of multiple AD9954 is active.
DDS0 Register – 0x7– Control Function Register
Setting
Linear
Sweep
Enable
(Bit 5)
Description
0
0
The linear frequency sweep capabilities are inactive.
1
1
The linear frequency sweep capabilities are active.
5.4.9 DDS0 Register – 0x8 – Control Function Register.
For more details, refer to AD9954 datasheet.
DDS0 Register – 0x8 – Control Function Register
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
RefClk Multiplier
VCO Range
Charge Pump Current
Default
‘00000’ ‘0’
‘00’
User Manual SMT399-160
Page 23 of 39
Last Edited: 24/05/2007 17:12:00