Adjusting the minimum gas flow, Service & maintenance instructions – ilve UP60 Majestic User Manual
Page 13

13
By-pass
r e g u l a -
ting
F i g u r e 1 4 b ( D U A L )
AUX
AUX
F i g u r e
1 3
F i g u r e 1 4 a
ADJUSTING THE MINIMUM GAS FLOW
When installing the cooker you must check that the minimum gas fl ow of the burners on the hob and in the oven is
correctly regulated. If the type of gas is changed it is indispensable to adjust the minimum fl ow. The regulating procedure
is as follows.
A) Burners on the hob (fig. 13)
1. Light one burner at a time and turn the flame up to maximum.
2. Remove the knob of the corresponding gas tap and insert screwdriver in the screw as showed in figure
14a or 14b (DUAL).
3. Turn the tap to minimum position.
4. Unscrew, turning to the left, to increase the flame, or screw to the right to decrease it.
5. If a liquid gas is used (Butane - Propane), the regulating screw must be fully screwed in.
SERVICE & MAINTENANCE INSTRUCTIONS
R e p l a c e m e n t P a r t s .
Authorized replacement parts may be used in performing service on the appliance. Replacement parts are available
from factory authorized part distributors.
S e r v i c e a n d m a i n t e n a n c e o n l y t o b e c a r r i e d o u t b y a n a u t h o r i s e d p e r s o n .
To replace parts such burners, valves and electric components, the hotplate must be removed from the bench
top by releasing the attachment hooks, loosening the attachment screws of each burner, unscrewing the hotplate
attachments nuts which are visible at the bottom of the surface, removing the hotplate top and fi nally replacing the
defective parts.
N o t e :
if the valves must be replaced, fi rst disassemble the ignitions switches wires.
It is recommended to replace the valve gaskets each time the valve is replaced.
WA R N I N G : A f t e r f i r s t i n s t a l l a t i o n o f t h e a p p l i a n c e o r a f t e r a ny s e r v i c e i n t e r ve n t i o n c o n c e r n i n g m a i n g a s p a r t s o f t h e
a p p l i a n c e, m a ke t h e l e a k t e s t u s i n g wa t e r w i t h s o a p a n t h e g a s c o n n e c t i o n s i n o r d e r t o ve r i f y t h e c o r r e c t i n s t a l l a t i o n .
D o n o t u s e f i r e fo r g a s l e a k t e s t i n g .
N O N W O R K I N G A P P L I A N C E S
Before calling the After Sales Service, check that the appliance is connected or that the main switch is activated.
After, call the After Sales Service. The faults must be checked by a skillfull technician.
R e m a r k :
the appliance is equipped with a safety thermostat, adjusted at a certain temperature. In case it reaches a
higher temperature, the appliance switches off.
- UP70 Majestic UM70 Majestic UP76 Majestic UM76 Majestic UP90 Majestic UPD90 Majestic UQDC90 Majestic UM90 Majestic UPD100 Majestic UQDC100 Majestic UMD100 Majestic UP120 Majestic UPD120 Majestic UM120 Majestic UMS120 Majestic UP150 Majestic UM150 Majestic UPN90 Nostalgie UPN76 Nostalgie UPN60 Nostalgie Nostalgie Collection 48 Inch Professional Freestanding Gas Range User Guide Professional Plus II 40 Inch Freestanding Dual Fuel Range Owner's Manual & Install Guide